Fujitsu MB95F430 Electric Heater User Manual


 
4 / 18
Induction Heater C Library User Manual Version 1.2
MCU-AN-500087-E-12
2. System Features
Power Control
Fan Control
Fan Delay Off
Buzz Control
Led Display
Keyboard
Kettle Detect
Kettle Empty Detect
Timing Power Off(3Hours)
Constant Power Heating
Constant Temperature Heating
IGBT Temp Detect
Plate Temp Detect
IGBT Temp Higher Protect(120)
Plate Temp Higher Protect(300)
Kettle Empty Protect(300)
Sensor Open/Short Detection
Over Current Protect(18A)
Over Voltage Protect(260V)
Lower Voltage Protect(150V)
Surge Protect(1000V)
No Operation for 2 Hours, auto turn off,if no timer
In the system design, we will use some feedback signals to protect system or calculate
watt. The protect signal include over current, over voltage, surge voltage and kettle detect.
Anyone of them appears, the system must stop work. If the IGBT temperature is raise over
60, the fan must turn on. If the IGBT temperature is raise over 120, the system must stop
work. If the kettle is empty, the plate temp will raise. If the temp raise up to 300, the system
must stop work.