Fujitsu fujitsu air conditioner concealed ceiling type Air Conditioner User Manual


 
En-7
TEMPERATURE SET BACK TIMER
Instructions related to heating are applicable to HEAT & COOL MODEL (Reverse Cycle).
To set the temperature SET BACK timer
1
SET BACK
SU
MO
TU
WE
TH FR
SA
369
12 15 18 21
If there is no existing
SET BACK tempera-
ture setting, - - will
be displayed for the
temperature.
2
SET
Press the SET BACK button to change to the SET BACK con rmation display.
The SET BACK operating time and the set temperature will be displayed.
Press the SET button for 2
seconds or more.
3
Day setting Operating time setting
DAY OFF
DAY
1
3
SET
2
SET
4
SU
MO
TU
WE
TH FR
SA
369
12 15 18 21
ex. When setting all days together
Follow steps
3 and 4 in To set the WEEKLY timer (p. 6). The DELETE button is also used as described in the procedures
for the weekly timer.
Temperature setting
4
76°F
76°F
84°F
SET BACK
temperature
Normal
temperature
SU
MO
TU
WE
TH FR
SA
369
12 15 18 21
Press the SET TEMPERATURE buttons to
set the temperature (from 48 °F to 88 °F).
ex. Operating time 3:0010:00 P.M.
(15:0022:00)
ON OFF
5
SET
Repeat steps 3 and 4.
Press the SET button for 2
seconds or more to com-
plete the temperature SET
BACK timer settings.
To start/cancel the temperature SET BACK timer operation
To start
SET BACK
SU
MO
TU
WE
TH FR
SA
ex. Display during SET BACK timer operation
(The operating time will not be displayed.)
To cancel
SET BACK
1
DELETE
2
Press the SET BACK button, and then press the DELETE
button while the SET BACK con rmation display is dis-
played. Even if the SET BACK button is pressed again, the
SET BACK timer will be cancelled.
Press the SET BACK button. The SET BACK con rmation
display appears for 5 seconds, and then the timer starts
automatically.
NOTES
(1) The SET BACK timer only changes the set temperature, it cannot be used to start or stop air conditioner
operation.
(2) The SET BACK timer can be set to operate up to two times per day but only one temperature setting can be
used.
(3) The SET BACK timer can be used together with the ON, OFF, and weekly timer functions.
(4) The SET BACK operating time is displayed only in the SET BACK con rmation display. (Refer to step 1 for the SET
BACK con rmation display.)
OM_9373117063-en.indd Sec1:7OM_9373117063-en.indd Sec1:7 9/10/07 5:16:13 PM9/10/07 5:16:13 PM