Fujitsu AST9 Air Conditioner User Manual


 
17
In Event of Power Interruption
TROUBLESHOOTING
Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).
Symptom
Doesn’t operate at all:
Poor Cooling (or *Heating)
performance:
The unit operates
differently from the
remote control unit’s
setting:
See page
9
7
5
CHECK ONCE
MORE
Items to check
Has the circuit breaker been turn off?
Has there been a power failure?
Has a fuse blown out, or a circuit breaker been tripped?
Is the timer operating?
Is the air filter dirty?
Are the air conditioner’s intake grille or outlet port blocked?
Did you adjust the room temperature settings (thermostat) cor-
rectly?
Is there a window or door open?
In the case of Cooling operation, is a window allowing bright sun-
light to enter? (Close the curtains.)
In the case of Cooling operation, are there heating apparatus and
computers inside the room, or are there too many people in the
room?
Is the unit set for SUPER QUIET operation?
Are the Remote Control Unit’s batteries dead?
Are the Remote Control Unit’s batteries loaded properly?
If the problem persists after performing these checks, or if you notice burning smells, or the TIMER indicator Lamp (Fig. 3 6)
flashes, immediately stop operation, turn off the circuit breaker, and consult authorized service personnel.
OPERATING TIPS
*Heating Performance
This air conditioner operates on the heat-pump principle,
absorbing heat from outdoor air and transferring that heat
indoors. As a result, the operating performance is reduced
as outdoor air temperature drops. If you feel that insuffi-
cient heating performance is being produced, we recom-
mend you use this air conditioner in conjunction with
another kind of heating appliance.
Heat-pump air conditioners heat your entire room by
recirculating air throughout the room, with the result that
some time may be required after first starting the air con-
ditioner until the room is heated.
*
When Indoor and Outdoor Temperatures are High
When both indoor and outdoor temperatures are high dur-
ing use of the heating mode, the outdoor unit’s fan may stop
at times.
*Microcomputer-controlled Automatic Defrosting
When using the Heating mode under conditions of low
outdoor air temperature high humidity, frost may form
on the outdoor unit, resulting in reduced operating per-
formance.
In order to prevent this kind of reduced performance, this
unit is equipped with a Microcomputer-controlled Auto-
matic Defrosting function. If frost forms, the air condi-
tioner will temporarily stop, and the defrosting circuit will
operate briefly (for about 7 to 15 minutes).
During Automatic Defrosting operation, the OPERATION
indicator lamp (red) will flash slowly.
Operation and Performance
If a power failure occurs during TIMER operation, the timer
will be reset and the unit will begin (or stop) operation at
the new time setting. In the event that this kind of timer
fault occurs the TIMER Indicator Lamp (green) will flash
(see page 4).
Use of other electrical appliances (electric shaver, etc.) or
nearby use of a wireless radio transmitter may cause the
air conditioner to malfunction. In this event, temporarily
disconnect the Power Supply Plug, reconnect it, and then
use the remote control unit to resume operation.
The air conditioner power has been interrupted by a
power failure. The air conditioner will then restart auto-
matically in its previous mode when the power is restored.
Operated by setting before the power failure.
AUTO Restart