Fujitsu AOU36CLX1 Air Conditioner User Manual


 
En-16
OPERATING TIPS
Dry Mode
About 14 to 115 °F
About 64 to 90 °F
Outdoor temperature
Indoor temperature
Cooling Mode
About 14 to 115 °F
About 64 to 90 °F
Temperature and Humidity Range
If the air conditioner is used under higher temperature conditioner than those listed, the built-in protection circuit may op-
erate to prevent internal circuit damage. Also, during Cooling and Dry modes, if the unit is used under conditions of lower
temperature than those listed above, the heat-exchanger may freeze, leading to water leakage and other damage.
Do not use this unit for any purposes other than the Cooling, Dehumidifying, and air-circulation of rooms in ordinary dwell-
ings.
If the unit is used for long periods under high-humidity conditions, condensation may form on the surface of the indoor
unit, and drip onto the fl oor or other objects underneath. (About 80% or more).
If the outdoor temperature is lower than the temperature scope in the list above, in order to keep safety operation of device,
the outdoor unit may stop operation for certain period of time.
SPECIFICATION
TYPE COOLING MODEL
MODEL INDOOR UNIT ASU30CLX1 ASU36CLX1
OUTDOOR UNIT AOU30CLX1 AOU36CLX1
POWER 208/230 V 60 Hz
COOLING
CAPACITY 30,700 Btu/h 33,000 Btu/h
INPUT POWER 3.24 kW 3.88 kW
CURRENT 14.2 A 17.0 A
9315345363_OM.indb Sec1:169315345363_OM.indb Sec1:16 9/16/2010 2:48:52 PM9/16/2010 2:48:52 PM