Fujitsu AOU36CLX1 Air Conditioner User Manual


 
En-12
Cleaning the Intake Grille
1. Remove the Intake Grille.
1 Place your fi ngers at both lower ends of the grille
panel, and lift forward; if the grille seems to catch part-
way through its movement, continue lifting upward to
remove.
2 Pull past the intermediate catch and open the Intake
Grille wide so that it become horizontal.
2. Clean with water.
Remove dust with a vacuum cleaner; wipe the unit with
warm water, then dry with a clean, soft cloth.
3. Replace the Intake Grille.
1 Pull the knobs all the way.
2 Hold the grille horizontal and set the left and right
mounting shafts into the bearings at the top of the
panel.
3 Press the place where the arrow on the diagram indi-
cates and close the Intake Grille.
1
2
CLEANING AND CARE
Before cleaning the air conditioner, be sure to turn it off and disconnect the Power Supply
Cord.
Be sure the Intake Grille (Fig. 1 8) is installed securely.
When removing and replacing the air fi lters, be sure not to touch the heat exchanger, as personal
injury may result.
CAUTION!
Cleaning the Air Filter
1. Open the Intake Grille, and remove the air
lter.
Lift up the air fi lter’s handle, disconnect the two lower
tabs, and pull out.
2. Remove dust with a vacuum cleaner or by
washing.
After washing, allow to dry thoroughly in a shaded
place.
3. Replace the Air Filter and close the Intake
Grille.
1 Align the sides of the air fi lter with the panel, and push
in fully, making sure the two lower tabs are returned
properly to their holes in the panel.
2 Close the Intake Grille.
(For purposes of example, the illustration shows the unit
without Intake Grille installed.)
Dust can be cleaned from the air fi lter either with a
vacuum cleaner, or by washing the fi lter in a solution of
mild detergent and warm water. If you wash the fi lter, be
sure to allow it to dry thoroughly in a shady place before
reinstalling.
If dirt is allowed to accumulate on the air fi lter, air fl ow will
be reduced, lowering operating effi ciency and increasing
noise.
During periods of normal use, the Air Filters should be
cleaned every two weeks.
When used for extended periods, the unit may accumulate dirt inside, reducing its performance. We recommend that the
unit be inspected regularly, in addition to your own cleaning and care. For more information, consult authorized service
personnel.
When cleaning the unit’s body, do not use water hotter than 104 °F, harsh abrasive cleansers, or volatile agents like ben-
zene or thinner.
Do not expose the unit body to liquid insecticides or hairsprays.
When shutting down the unit for one month or more, fi rst allow the fan mode to operate continuously for about one-half
day to allow internal parts to dry thoroughly.
Intake Grille
Air fi lter handle
Hooks (two places)
Intake
Grille
Hooks (two places)
Intake Grille
Mounting
shaft
Knob
Intake Grille
Bearing
Mounting shaft
Knob
1
2
2
1
Mounting
shaft
Knob
9315345363_OM.indb Sec1:129315345363_OM.indb Sec1:12 9/16/2010 2:48:51 PM9/16/2010 2:48:51 PM