Frigidaire FRS093LW1 Air Conditioner User Manual


 
07
8. The site must allow for the easy
removal of the connector pipe and
drain hose.
9. The unit must be installed at a site
protected from direct sunlight.
Precautions for Installation
Installation at the following sites may cause problems. If you must inevitably install
2. Sites with a high concentration of salinity, such as coastal areas.
3. Sites with sulfuric gas, such as hot water springs.
4. Sites with high frequency equipment, such as wireless equipment, welding
machines and medical installations.
5. Sites with flammable gases or volatile material.
6. Sites with special environmental conditions.
7. Laundry rooms.
Indoor Unit
1. The unit must be installed at a site
that does not obstruct the flow of
air.
2. The site must support the weight of
the indoor unit.
3. The site must be easily accessible
for maintenance and replacement
of the air filter.
4. The site must allow for the
necessary space around the indoor
figure.
that the unit be installed at the
Choosing the installation site
More
More
More
More
Choosing the installation site
the unit at one of these sites, please consult your local distributor beforehand:
1. Sites with machine oil.
unit, as shown in the sideward
meter) between the unit and radio
5. There should be at least 3 feet (1
feet (2.3 meters) from the ground.
flammable gases.
7. The indoor unit must be at least 7.5
6. It must be far from fire, smoke or
center.
or television devices. It is ideal
than 6"
than 5"
than 7.5'
than 5"
1. Carefully read the installation manual before beginning.
2. Follow each step as shown.
4. Pay attention to danger and safety notices
Installation Warnings
3. Observe all local, state and national electric codes. This appliance must be
installed by a qualified licensed HVAC technician in accordance with all
applicable codes. All electrical connections should be performed by a licensed
electrician.