3. INSTALLATION
3.1 INSTALLATION HARDWARE
Type C (5)
Type A (13)
Bolt (2)
Nut (2)
Type B (3)
Foam top
window gasket
Window sash seal
Right frame
curtain
Window locking
bracket
Left frame curtain
Frame guide(2)
Sill support(2)
3.2 SELECT THE BEST LOCATION
Step 1. To prevent vibration and noise, make sure the unit is
installed securely and firmly
Step 2. If possible, install the unit where sunlight does not shine
directly on the unit.
Step 3. The outside of the cabinet must extend
outward for at least 11" and there should be no
obstacles, such as a fence or wall, within 20" from the
back of the cabinet because it will prevent heat
radiation of the condenser.
Restriction of outside air will greatly reduce the cooling
efficiency of the air conditioner.
Step 4. Install the unit with a little tilt outward not to leak the
condensed water into the room (about 10~15cm or 1/4
bubble with level).
CAUTION: All side louvers of the cabinet must remain exposed
to the outside of the structure.
Over 20"
About 1/2"
HEAT
RADIATION
FENCE
AWNING
COOLED
AIR
30"~60"
Level
1/4 Bubble