Friedrich UE10C33 Air Conditioner User Manual


 
Service Manual 13
Disassembly Instructions
12. CONDENSER
1. Remove the cabinet. (Refer to section 2)
2. Remove the brace and the shroud cover.
(Refer to section 4)
3. Remove the 5 screws which fasten the condenser.
4. After discharging the refrigerant completely,
unbraze the interconnecting tube at the condenser
connections.
5. Remove the condenser.
6. Re-install the components by referring to notes.
(See Fig. 15)
13. EVAPORATOR
1. Remove the cabinet. (Refer to section 2)
2. Discharge the refrigerant completely.
3. Remove the 2 screws which fasten the evaporator
at the left side and the right side.
4. Move the evaporator sideward carefully and then
unbraze the interconnecting tube at the evaporator
connectors.
5. Remove the evaporator.
6. Re-install the components by referring to notes.
(See Fig. 16)
14. CAPILLARY TUBE
1. Remove the cabinet. (Refer to section 2)
2. After discharging the refrigerant completely,
unbraze the interconnecting tube at the capillary
tube.
3. Remove the capillary tube.
4. Re-install the components by referring to notes.
FIG. 15
FIG. 16
Refrigerating Cycle
Discharge the refrigerant system using Freon
TM
Recovery System.
If there is no valve to attach the recovery system,
install one (such as a WATCO A-1) before vent-
ing the Freon
TM
. Leave the valve in place after
servicing the system.
CAUTION
MODE
TIMER
POW
ER
FAN
SPEED
Fan
Energy
Saver
Cool
Timer
TEM
P
'
F
F1 LOW
F2 MED
F3 HIGH