PERFORMANCE DATA
*
Installation Information / Sleeve Dimensions
* Minimum extensions when mounted in a window.
** Minimum widths achieved using one side curtain assembly as opposed to both in a standard installation.
Circuit Rating / Breaker
(B)
(C)
Fro nt
SIDE VIEW
Model
Circuit Rating
Bre ake r or
T-D Fuse
Plug
Fac e
(NEMA#)
Po wer Cord
Length (ft.)
Wall O utlet
Appearance
SQ05N10
*
, SQ06N10
*
,
SQ08N10
*
, SQ10N10
*
EQ 0 8N 11
*
7
125V - 15A 5 - 15P 6
Sleeve Height Width
Depth
with Front
Shell Depth to
Louvers
Minimum
Extension
Into Room*
Minimum
Extension
Outside*
Window Width
Thru-the-wall Installation
Finished Hole
Minimum** Maximum Height Width Max. Depth
Q 14"
19
"
21
3
8
"
8
"
5
"
10
"
22" 42" 14 "20" 8 ”
As an ENERGY STAR
®
partner, Friedrich Air Conditioning Co. has determined that the selected ENERGY STAR
®
models
meet the ENERGY STAR
®
Estimated yearly operating cost based on a 2007 national average electricity cost of 10.65 cents per kWh.
Model
Cooling
Capacity Btu
Heating
Capacity Btu
Volts
Rated
Cooling
Amps
Cooling
Watts
Heating
Amps
Heating
Watts COP
Energy
Ratio
EER
Estimated
Yearly
Operating
Cost
Moisture
Removal
Pints/HR
Room Side
Air
Circulation
CFM Sleeve
Net
Weight Ship
Wt Lbs
Kühl ®
SQ
SQ
SQ
SQ
05N10
*
5500 — 115 4.5 514 — — 10.7 $41 0,5 190 Q 65
71
71
75
78
84
84
88
06N10
*
5900 — 115 4.9 561 — — 18.7 $45 0.5 190 Q
08N10
*
7500 — 115 6.1 700 — — 10.7 $56 1.2 240 Q
10N10
*
9500 — 115 8.4 969 — —
9.8 $77 2.1 240 Q
Kühl+®
Electric Heat
EQ08N11
*
7500 4000 115 6.9 765 11.2 1290 1.9 11.7 $61 1.9 175 Q 72 84
Window Mounting Kits
Heat/Cool Models Kit No.
EQ 0 8 N11
*
WIKQ
Friedrich heat/cool models include accessories for
thru-the-wall installation only. Window mounting requires
use of optional accessory kit as listed above.
USC
6
COOLING
PERFORMANCE DATA**
EVAP. AIR TEMP. DEG. F
CONDENSER
TEMPERATURE DEG. F
Discharge Temp Suction Temp Super Heat Sub-Cooling
OPERATING PRESSURES ELECTRICAL RATINGS
R-410A
REF.
Voltage
BREAKER FUSE
Discharge Air
Temp.
Drop F.
Suction Discharge Amps Cool Amps Heat
Locked Rotor
Amps
Charge in
OZ.
60 Hertz Amps
Q-Chassis
SQ05N10-A
57 23 115 146 63 10 13 158 387 9 29.0 17.0 115 15
SQ06N10-A 57 23 115 146 63 10 13 150 387 4.9 29.0 17.0 115 15
SQ08N10-A 58 23 118 158 63 12 20 147 415 6.6 32.0 22.0 115 15
SQ10N10-A 53 22 122 164 58 11 23 136 428 9.2 50.0 23.5 115 15
EQ08N11-A 53 27 117 159 61 20 19 146 411 6.7 11.2 32.0 18.5 115 15
5DWLQJ&RQGLWLRQVGHJUHHV)URRPDLUWHPSUHODWLYHKXPLGLW\ZLWKGHJUHH)RXWVLGHDLUWHPSUHODWLYHKXPLGLW\DOOV\VWHPVXVH5$
*
'XHWRFRQWLQXLQJUHVHDUFKLQQHZHQHUJ\VDYLQJWHFKQRORJ\SHUIRUPDQFHGDWDDQGWKDQGWKFKDUDFWHUDUHVXEMHFWWRFKDQJHZLWKRXWQRWLFH