STEP 6. Inspect the unit before inserting it into the sleeve. The fan
should be manually rotated to insure that they turn freely. Be
sure the electrical cord will be out of the way when inserting
the unit into the sleeve.
NOTE: For your safety, DO NOT plug the electrical cord into an electrical
outlet until installation is complete.
STEP 7. If the unit checks out OK, it is ready to be placed into position
on bottom rails of the cabinet and pushed into place.
NOTE: Do all lifting of the unit by the bottom pan only and with assistance
or help as necessary (See Figure 14).
STEP 8. The chassis must be pulled out slightly, so that there is a gap
of 1 1/2" between the unit and shell (See Figure 16).
STEP 9. Install the white chassis seal gasket (item #6, page 22) and
the gray window seal gasket (item #5). Carefully insert the
white gasket (item #6) between the chassis and the cabinet
starting at either bottom corner and go up the side, across
the top and down the opposite side. Insert the gray gasket
(item #5) between the window sashes as shown in Figure
16. If chassis seal gasket is not installed, the operation of the
unit will be negatively affected. Also, the operation noise and
outside noise will be ampli ed.
STEP 10. Hold the decorative front as shown in Figure 17. Insert the two
tabs of the Decorative Front Panel into the slots in the top of
the cabinet and lower the bottom of the decorative front to the
bottom of the cabinet. Route the electrical cord to the right or
left side of the bottom of the cabinet as required by the location
of the electrical wall outlet. Use the notches provided at the
bottom of the Decorative Front Panel for routing the electrical
cord out of the unit. Attach the decorative front to the cabinet
with two (2) No. 8 x ½" Phillips head screws (item #2, page 22).
WARNING
Electrical Shock Hazard
Make sure your electrical receptacle has the
same configuration as your air conditioner’s
plug. If different, consult a Licensed Electrician.
Do not use plug adapters.
Do not use an extension cord.
Do not remove ground prong.
Always plug into a grounded 3 prong oulet.
Failure to follow these instructions can result in
death, fire, or electrical shock.
FRR087
SCREW, 1/2” PHILLIPS HEAD
(SEE ILLUSTRATION,
ITEM #2, PAGE 22)
SCREW, 1 1/4” PHILLIPS HEAD
(SEE ILLUSTRATION,
ITEM #4, PAGE 22)
SCREW, #8 x 7/8” HEX HEAD
(SEE ILLUSTRATION,
ITEM #3, PAGE 22)
WINDOW STOOL
SHELL SUPPORT CHANNEL
WINDOW SASH
CABINET
SILL
CHANNEL
SECTION A-A
A
A
STEP 11. CIRCUIT PROTECTION - If the air conditioner is circuit
protected by a fuse, use a "TIME DELAY" fuse or HACR type
Circuit Breaker due to momentary high current demand when
your air conditioner is started. Before operating your unit, verify
the ampere rating of the time-delay fuse or circuit breaker
which protects your unit. The ampere rating of the time-delay
fuse or circuit breaker shall be 15 amps. Refer to Operation
section for more detailed operating instructions.
NOTE: Remove tape and verify lter is intact, as per lter instructions
found inside door.
Figure 15