Friedrich SQ05 Air Conditioner User Manual


 
29
STEP 7. &XWWZRSLHFHVRIVWDQGDUGOXPEHUVXSSOLHGE\LQVWDOOHU
to the length and width required. Place in front and back of
bottom sill channel as shown in Figure 24. Secure with nails
(supplied by installer).
STEP 8. Seal all holes in the cabinet with caulking compound (supplied
by installer).
STEP 9. &RPSOHWHWKHLQVWDOODWLRQE\IROORZLQJ67(36WKURXJKRI
6WDQGDUG:LQGRZ,QVWDOODWLRQ3DJH:LQGRZ6HDO*DVNHW
mentioned in STEP 9 will not be required.
IMPORTANT:%HIRUHRSHUDWLQJ\RXUXQLWUHDG67(3RI6WDQGDUG
Window Instructions.
FRR092
3/4” MINIMUM
CABINET FRONT
1” THICK LUMBER
1” MINIMUM
INSIDE WALL
EXTERIOR WALL
MAX. WALL
THICKNESS
ALLOWED 8-1/2
7/8” SLOTTED HEAD SCREWS (3 EA. SIDE)
NAILS MAY BE USED IF DESIRED.
3/4” MINIMUM FRONT
EDGE OF CABINET TO
INSIDE WALL SURFACE.
FRONT EDGE OF LOUVERS
MUST ALWAYS BE OUTSIDE OF
EXTERIOR WALL SURFACE.
TRIM AROUND THE
CABINET WITH A
SUITABLE WOOD
MOULDING AND
FINISH TO SUIT.
CAULK ALLAROUND
CABINET ON OUTSIDE
TO INSURE A WEATHER
TIGHT SEAL.
1/4” SLOPE DOWN.
POSITION AND SECURE
CABINET DOWNWARD.
SLOPE OUTSIDE FOR
DRAINAGE.
FRR093
CAULK ALL SIDES
CABINET
ELECTRICAL
RECEPTACLE
MORTAR
NOTE: ELECTRICAL RECEPTACLE LOCATION
FROM POINT “X” MUST BE WITHIN A MAXIMUM
RADIUS OF 69” FOR 115V UNITS.
POINT “X”
SOLID MASONRY CONSTRUCTION
Figure 24
Figure 25