5
Permanent Split-Capacitor, totally enclosed fan motor to
assure efſcient operation even under adverse electrical
conditions. Motorhas a specialstainlesssteelshafttoresist
corrosion and a hermetically sealed overload for arc-free
operation.
High capacitycompressorwithinternalhermeticallysealed
overload.
Hot gas bypass low ambient control to permit operation
without freezing at outdoor ambient temperatures as low
as 45°F (7°C).
Environmentally sealed on-off switch and gold plated
contacts in thermostat for corrosion resistance.
Friedrich Air Conditioning quality has been proven by more than 25 years of successful experience from the Gulf of Mexico to
the searing sands of the Arabian desert.
Hazardgard Special Features
Copper tubing/aluminum ſn coils.
Galvanized steel cabinet and base pan, all bonderized.
Slide-out chassis for easy installation in window or
through–the–wall.
Extra insulation inside, including completely insulated
plenum chamber for quieter, more efſcient cooling.
Entire unit test run in environmental chamber before
crating.
Eight–way air ƀow control for uniform air circulation.
Condensate drain with exclusive mosquito trap.
15ampcircuitwithtime-delayfuserequired. Accommodates
direct wiring.
Long lasting 3/8" (10 mm) thick air ſlter, germicidally
treated, easily removed for cleaning.
Control Panel
Function Control (Power)
This switch is a double pole, single throw toggle switch.
ON - Turns everything on.
OFF - Turns everything off.
Temperature Control
The knobatthebottom is the thermostatwhichisa crossambient
type used to maintain the desired comfort level. The thermostat
reacts only to a change in temperature at the bulb location - turn
the knob clockwise to set cooler, counterclockwise for warmer.
Exclusive
Friedrich leads with the ſrst UL Listed Room Air Conditioners
designed to cool living quarters and other enclosures situated in
hazardous locations where speciſc volatile ƀammableliquidsor
gases are handled or used with enclosed containers or systems.
Friedrich Hazardgard room air conditioners are designed to
meet the National Electrical Code, Article 500 requirements
for Class I, Division 2, Groups A, B, C, D Hazardous locations,
THIS UNIT IS LISTED BY UNDERWRITERS LABORA-
TORIES FOR USE IN CLASS I, DIVISION 2, GROUPS A,
B, C,D HAZARDOUSLOCATIONS. Operating Temperature
Code: T3B.
Contains transient voltage suppressor to protect
controls against transient voltage spikes. Provides
solid state switches for arc-free operation.
Polyester powder finish, over-baked for an attractive,
long-lasting finish.