Friedrich SH15 Air Conditioner User Manual


 
4
Filter Information
The ſlter in your Friedrich removes dust, pollen and other
impurities from the air as they are drawn through the unit.
The ſlter is permanent and reusable, and has a germicidal
treatment which is not affected by washing.
Won’t Cool
If the unit operates, but doesn’t cool, check to see that the con-
trols are properly set. Inspect the ſlter and clean it thoroughly, if
needed. Check to see if the chassis seal gasket is installed (refer
to installation instructions).
Won’t Run
If the unit does not operate at all, check that the power supply
connections are tight. Check for blown fuses or tripped circuit
breakers. Replace blown fuses with the proper size time-delay
fuse.Thenameplateon the unit showsthe proper fusesize. After
restoring power, wait three minutes before restarting the unit.
Inside Coil Freezes Up
YourFriedrichHazardgardisdesignednottofreezewithoutdoor
temperatures as low as 45°F (7°C). Freezing should only occur
whentheoutsideair is damp and below 45°F (7°C). Iftheindoor
Maintenance Checklist
coilshouldiceoverwhilecooling,set thethermostatto thewarm-
estpositionuntiltheiceonthecoilis gone. Setting thethermostat
to aslightly warmerpositionwillprobablykeep ice from forming
on the coil. A dirty ſlter will contribute to icing.
Cleaning
The front grille of your Friedrich, as well as the complete cabi-
net may be cleaned with warm water and a mild detergent. The
coils and base pan should be cleaned periodically for the most
efſcient operation. We suggest you call your Friedrich dealer
for this service.
Lubrication
Fan motors are factory lubricated and sealed. No lubrication
is required.
A clogged, dirty ſlter reduces the air ƀow through the unit and
reduces its efſciency. You should check the ſlter every seven
to ten days, depending on the amount your unit is used. Clean
the ſlter regularly.
FILTER RETAINER CLIPS
The
lter can be removed for cleaning by opening the front of
the unit and releasing the
lter from its retaining clips.