Friedrich RC 11 Air Conditioner User Manual


 
25
www.retroaire.com
The Right Fit For Comfort
Due to EMI’s ongoing development programs, design, specifications, and performance data may change without notice.
SPECIFICATIONS FOR THE RC/RH10/20/35/45/80/90 & RC11/12/21
When installing the RC/RH10/20/35/45/80/90 or the RC11/12/21 refer to
the charts below for electrical and optional electric heat specifications.
* Note: Data will vary if alternate components (including compressor or motor) are used to meet production needs.
Consult factory for current electrical specifications.
RC/RH10/20/35/45/80/90 & RC11/21 Electrical Specifications*
Model
Voltage/hz/ph
Evap Motor Cond Motor Compressor Total
MCA Max Fuse
Min
Voltage
Line Cord
Number FLA Hp FLA Hp RLA LRA Amps
9
115/60/1
1.4 0.09 1.6 0.125 7.4 44 10.4 12.3 15 104 5-15P
208/230/60/1 0.6 0.08 0.72 0.125 4.1 20 5.4 6.4 15 197 6-15P
265/60/1 0.67 0.08 0.7 0.125 3.35 18 4.7 5.6 15 240 7-20P
12
115/60/1
1.4 0.09 1.6 0.125 9.7 54 12.7 15.1 20 104 5-20P
208/230/60/1 0.6 0.08 0.72 0.125 5.1 28 6.4 7.7 15 197 6-15P
265/60/1 0.67 0.08 0.7 0.125 4.25 26 5.6 6.7 15 240 7-20P
15
208/230/60/1 0.6 0.08 0.72 0.125 6.4 35 7.7 9.3 15 197 6-15P
265/60/1 0.67 0.08 0.7 0.125 5.4 32 6.8 8.1 15 240 7-20P
18
208/230/60/1 0.6 0.08 0.71 0.09 7.6 45 8.9 10.8 15 197 6-15P
265/60/1 0.67 0.08 0.71 0.09 6.3 32 7.7 9.3 15 240 7-20P
Note: 18,000 not available in heat pump application.
NEMA Specifications Non-Locking/Receptacles
RC/RH10/20/35/45/80/90 & RC11/12/21 Optional Electric Heat Specifications*
Heater No. Voltage Watts Btuh Amps
Total Heat
MCA
Max
Fuse
Line
Cord
Amps
2
208 1636 5600 7.9 8.5 10.4 15 6-15P
230 2000 6900 8.7 9.3 11.5 15 6-15P
265 2655 9100 10.0 10.7 13.2 15 7-20P
3
208 2454 8400 11.8 12.4 15.3 20 6-20P
230 3000 10300 13.0 13.6 16.9 20 6-20P
265 3983 13600 15.0 15.7 19.5 20 7-20P
4
208 3271 11200 15.7 16.3 20.3 25 6-30P
230 4000 13700 17.4 18.0 22.3 25 6-30P
265 5310 18200 20.0 20.7 25.7 30 7-30P
5
208 4089 14000 19.7 20.3 25.2 30 6-30P
230 5000 17100 21.7 22.3 27.8 30 6-30P
RC12 Electrical Specifications*
Model
Voltage/hz/ph
Evap Motor Cond Motor Compressor Total
MCA
Max
Fuse
Min
Voltage
Line
Cord
Number FLA Hp FLA Hp RLA LRA Amps
12
208/230/60/1 0.6 0.08 0.71 0.09 5.1 28 6.4 7.7 15 197 6-15P
265/60/1 0.67 0.08 0.71 0.09 4.25 26 5.6 6.7 15 240 7-20P
15
208/230/60/1 0.6 0.08 0.71 0.09 7.6 45 8.9 10.8 15 197 6-15P
265/60/1 0.67 0.08 0.71 0.09 6.3 32 7.7 9.3 15 240 7-20P