Friedrich MW09C1H Air Conditioner User Manual


 
31
(10) Display
Operation pattern and mode pattern display
All the display patterns will display for a time when the unit is power de on, the operation indication icon will display in red under
standby status. When the machine is start by remote controller, the indication icon will light and display the current
operation mode (the mode light includes: Cooling, heating and dry). If you close the light key, all the display icons
will close.
Double-8 display
According to the different setting of remote control, the nixie lamp may display the current temperature (the temperature
scope is from 61°F to 86°F ) and indoor ambient temperature. The heating and air supply temperature will display 77°F
under auto-mode, the temperature will display 64
under the heating mF ode, and the temperature will display H1 under the
defrosting mode.(If you set the fahrenheit temperature displa
y, the nixie lamp will display according to fahrenheit
temperature)
(11) Protection function and failure display
E2: Freeze-proofing protection E4: Exhausting protection E5: Overcurrent protection
E6: Communication failure E8: Overload protection
F1: Indoor ambient sensor start and short circuit (continuously measured failure in 30S)
F2: Indoor evaporator sensor start and short circuit (continuously measured failure in 30S)
F3: Outdoor ambient sensor start and short circuit (continuously measured failure in 30S)
F2: Outdoor condenser sensor start and short circuit (continuously measured failure in 30S, and don’t measure within 10
minutes after defrosted)
F5: Outdoor exhausting sensor start and short circuit (continuously measured failure in 30S after the compressor operated 3
minutes)
H3: Overload protection of compressor H5: Module protection
PH: High-voltage protection PL: Low-voltage protection
P1: Nominal cooling and heating P2: Maximum cooling and heating
P3: Medium cooling and heating P0: Minimum cooling and heating
(12) Drying Function
You may start or stop the dry function under the modes of cooling and dry at the starting status (The modes of
automatism, heating and air supply do not have dry function). When you start the dry function, after stop the
machine by pressing the switch button, you should keep running the infoor fans for 10 minutes under low air damper (The
swing will operate as the former status within 10 minutes, and other load is stopped), then stop the entire machine; When
you stop the dry function, press the switch button will stop the machine directly.
When you start the drying function, operating the drying button will stop the inner fans and close the guide louver.
(13) Memory function when interrupting the power supply
Memory content: mode, swing function, light, set temperature and wind speed.
After interrupted the power supply, the machine will start when recovering the power according to the memory content
automatically. If the last
remote control command has not set the timed function, the system will remember the last remote
control command and operate according it. If the last remote control command has set timed function and the power supply
is interrupted before the timed time, the system will remember the timed function of the last remote control command, the
timed time will recounted form power on. If the last remote control command has set timed function, the time is out and the
system is start or stop according to the set time when the power supply is interrupted, the system will remember the
operation status before the power supply was interrupted, and do not carry out timed action; The timed clock will not be
remembered.
Heating angle
Cooling angle
Function and Control