Installation Manual
Installing Mounting Plate
1.Make the mounting plate completely level
. As
the water tray's oulet of the indoor unit is two-way type, the
indoor unit during installation should slightly slant to watert tray's outlet for smooth drainage of condensing
water.
2.Fix the mounting plate on the wall with screws.(Where is pre-covered with plastic granula)
3.Be sure that the mounting plate has been fixed firmly enough to withstand the weight of an adult of 60kg;
further more, the weight should be evenly shared by each screw.
Fig.5
Wall
Wall
Mark on the middle of it
Gradienter
Left
Right
(Rear piping hole)
(Rear piping hole)
Space
to the
wall
6 in
above
Space
to the
wall
6 in
above
Fig.6
Ø
55
Boring Piping Hole
Installing Drain Hose
Wrenched Bent
Flooded
Indoor Outdoor
Wall pipe
Seal pad
Connecting Indoor and Outdoor Electric Wires
1.Make the piping hole (2.5 in) in the wall at a slight downward slant to the
outdoor side.
2.Insert the piping-hole sleeve into the hole to prevent the connection piping
and wiring from being damaged when passing through the hole.
1.For proper draining, the drain hose should be placed at a downward slant.
2.Do not wrench or bend the drain hose or flood its end by water.
3.The long drain hose passing through indoor areas should
be wrapped with insulation material.
1.Open the front panel.
2.Remove the wiring cover as shown in Fig 6.
3.Make the power connection cord and signal control wire (onlyf or heat pump unit ) through the hole in the
4.Reinstall the clamp and wiring cover.
5.Recovert he front panel.
the back of indoor unit.
2.5 in2.5 in
39
(only for heat pump unit) through the hole in the