Friedrich CP18 Air Conditioner User Manual


 
4
B
C
C
A
D
Power supply
cord Wiring requirements
115-volt (103.5 min. - 126.5 max.)
0-12 amps
15-amp time-delay fuse or circuit breaker
Use on single outlet circuit only.
230-volt (207 min. - 253 max.)
0-12 amps
15-amp time-delay fuse or circuit breaker
Use on single outlet circuit only.
¹⁄₄"
(0.6 cm)
The wall opening measurements should be:
Height (A): 17 ¼" plus twice thickness of wood used to build
frame
Width (B): 26 ¼"
Depth (D): 4" minimum to 8" maximum.
Electrical Requirements
Ground wire must be connected to ground screw located in lower
right corner of air conditioner when air conditioner is in cabinet.
The electrical ratings for your air conditioner are listed on the
model and serial number (nameplate) label. The model and serial
number label is located behind the front panel on the flange below
the control panel area.
Specific electrical requirements are listed in the chart below.
Follow the requirements for the type of plug on the power supply
cord.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove powercord ground prong.
Do not use a plug adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Window installation
Window opening measurements:
27"min. to 42" max. (76.2 cm to 101.6 cm) opening width (A).
20" min. (50.8 cm) opening height (B).
Through-the-wall installation
A.27"min.(76.2cm)
B.20" min. (50.8 cm)
A
B
A. 17 ¼"
B. 26 ¼"
C. Wood thickness
D. 4" minimum to
8" maximum.
CP14
CP18 / CP24