Friedrich CP05 CP Line Air Conditioner User Manual


 
10
TYPE A
TYPE A
ROOM SIDE
CENTER LINE
OUTSIDE
INSIDE
L
BRACKET
OUTER SILL
SHORT SIDE
INNER SILL
TYPE A
8"
8"
INNER SILL
CENTER LINE
SEAL STRIP
(TYPE D)
CENTER LINE
A. BEFORE INSTALLATION
1. Insert the guide panels into the guides of the air
conditioner. Fasten the curtains to the unit with
screws (TYPE A) as shown Fig. 6.
2. Cut the adhesive-backed seal strip (TYPE D) to
match the window width.
Remove the backing from the seal strip and attach
the seal strip to the underside of the bottom
window. (Fig. 7)
B. BEGIN INSTALLATION
1. LOCATING UNIT IN WINDOW
Open the window and mark center line on the
center of the inner sill, as shown in Fig. 8.
2. ATTACH L BRACKET
a. Install the L brackets behind the inner window
sill, with the short side of bracket as shown.
Use the 2 screws (TYPE A) provided.
b. The bracket helps to hold unit securely in place.
Be sure to place bracket edge flush against back
of inner sill. See Fig. 9.
3. INSTALL THE AIR CONDITIONER IN THE WINDOW
a. Carefully lift the air conditioner and slide it into
the open window. Make sure the bottom guide of
the air conditioner drops into the notches of the
L bracket. See Fig. 9.
IMPORTANT :
When the air conditioner drops into the L bracket, the
air conditioner will be centered in window opening as
shown in Fig. 10.
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
During the following step, hold unit firmly until
window sash is lowered to top channel behind
side panel frames. Personal injury or property
damage may result if unit falls from window.
CAUTION