Franke Consumer Products FQD 907 Indoor Furnishings User Manual


 
EN
1
9
19
Mounting the hood body
Open the ducting panels.
• Disconnect the panel from the hood canopy by slid-
ing the fixing pin lever.(A)
• Remove the metal grease filters by turning the han-
dles provided.
Adjust the two screws Vr, on brackets 11a, to a mini-
mum.(B)
Hook the hood canopy onto the two brackets 11a.
From inside the hood canopy, adjust the screws Vr to
set the Hood Canopy level.
Tighten the safety screw 11.
(A)
(B)
Vr
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to
the chimney using either a flexible or rigid
pipe ø 150 mm, the choice of which is left to the in-
staller.
Fix the pipe in position using sufficient pipe
clamps (not supplied).
Remove any activated charcoal filters.
ø 150
RECIRCULATION VERSION AIR OUTLET
To install the Recirculation Version of the hood, the
optional Activated charcoal cartridge kit must be pur-
chased.
• Screw the filter cover onto the air outlet, using four
screws 12c (2.9 x 12.5).
• Fix the directional grille 8 on the recirculation air
outlet using the 2 screws 12d (2,9 x 9,5) provided.
16
12c
12d
8