3
105073
OWNER’S MANUAL
Figure 1 - Ember Master
Front
Logs
Control Knob
Rear Log
Base
Assembly
Front
Burner
Piezo
Ignitor
Rear
Burner
Crossover Log
Bottom
Middle
Log
Selector Switch
(Optional)
Flame
Adjustment
Knob
PRODUCT
IDENTIFICATION
LOCAL CODES
Install and use heater with care. Follow all
local codes. In the absence of local codes, use
the latest edition of The National Fuel Gas
Code, ANS Z223.1, also known as NFPA 54*.
*Available from:
American National Standards Institute, Inc.
Batterymarch Park
New York, NY 10018
National Fire Protection Association, Inc.
1430 Broadway
Quincy, MA 02269
Note:
Where listed vented decorative logs
are required, thermostat operation is not
permitted.
14. Do not operate heater if any log is bro-
ken. Do not operate heater if a log is
chipped (dime-sized or larger).
15. Turn heater off and let cool before ser-
vicing, installing, or repairing. When
using the hand-held remote accessory,
make sure the selector switch is in the
OFF position. Only a qualified service
person should install, service, or repair
heater.
16. When using the hand-held remote acces-
sory, make sure the selector switch is in
the OFF position when you are away
from home for long periods of time.
17. This heater must not be connected to
any external electrical source.
18. Operating heater above elevations of
4,500 feet may cause pilot outage.
19. To prevent performance problems, the
use of a propane/LP fuel tank of less than
100 lb. capacity is not recommended.
SAFETY
INFORMATION
Continued
PRODUCT
FEATURES
OPERATION
This heater is clean burning. It requires no
outside venting. There is no heat loss out a vent
or up a chimney. Heat is generated by both
realistic flames and glowing coals. This heater
is designed for vent-free operation with flue
damper closed. It has been tested and ap-
proved to ANS Z21.11.2 standard for
unvented heaters. State and local codes in
some areas prohibit the use of vent-free heat-
ers. This heater may also be operated as a
vented decorative (ANS Z21.60) product by
opening the flue damper (non-thermostat
operation only).
SAFETY PILOT
This heater has a pilot with an Oxygen
Depletion Sensing(ODS) safety shutoff sys-
tem. The ODS/pilot is a required feature for
vent-free room heaters. The ODS/pilot shuts
off the heater if there is not enough fresh air.
PIEZO IGNITION SYSTEM
This heater has a piezo ignitor. This system
requires no matches, batteries, or other
sources to light heater.
Top Middle Log
UNPACKING
CAUTION: Do not remove the
metal data plates from the grate
assembly. The dataplates contain
important product information.
1. Remove logs and heater base assem-
bly from carton.
Note:
Do not pick up
heater base assembly by the burner.
This could damage heater. Always
handle base assembly by grate.
2. Remove all protective packaging ap-
plied to logs and heater for shipment.
3. Check all items for any shipping dam-
age. If damaged, promptly inform
dealer where you bought heater.
Continued