FMI VFP30R Indoor Fireplace User Manual


 
21
105073
OWNER’S MANUAL
REPLACEMENT
PARTS
Note:
Use only original replacement parts.
This will protect your warranty coverage for
parts replaced under warranty.
PARTS UNDER WARRANTY
Contact authorized dealers of this product.
If they can’t supply original replacement
part(s), call Fireplace Manufacturers
Incorporated’s Technical Service Depart-
ment at 1-888-427-8322.
When calling Fireplace Manufacturers In-
corporated, have ready
your name and address
model and serial numbers of your heater
how heater was malfunctioning
type of gas used (propane/LP or natural gas)
purchase date
Usually, we will ask you to return the defec-
tive part to the factory.
PARTS NOT UNDER
WARRANTY
Contact authorized dealers of this product.
If they can’t supply original replacement
part(s), call Fireplace Manufacturers
Incorporated’s Parts Department at 1-800-
888-2050 for referral information.
When calling Fireplace Manufacturers In-
corporated, have ready
model and serial numbers of your heater
the replacement part number
SPECIFICATIONS
SERVICE HINTS
When Gas Pressure Is Too Low
pilot will not stay lit
burners will have delayed ignition
heater will not produce specified heat
propane/LP gas supply may be low
When Gas Quality Is Bad
pilot will not stay lit
burners will produce flames and soot
heater will backfire when lit
You may feel your gas pressure is too low or
gas quality is bad. If so, contact your local
propane/LP gas supplier.
WIRING DIAGRAM
18" Variable 24" Variable 30" Variable
Btu (Variable) 16,000/26,000 20,000/33,000 21,5000/36,000
Type Gas Propane/LP Only Propane/LP Only Propane/LP Only
Ignition Piezo Piezo Piezo
Manifold Pressure 7.9" W.C. 7.9" W.C. 7.9" W.C.
Inlet Gas Pressure
(in. of water)
Maximum 14" 14" 14"
Minimum* 11" 11" 11"
Shipping Weight 32 lbs. 34 lbs. 36 lbs.
* For purpose of input adjustment
TECHNICAL
SERVICE
You may have further questions about in-
stallation, operation, or troubleshooting.
If so, contact DESA International’s Techni-
cal Service Department at 1-800-DESA LOG
(1-800-337-2564).
You can also visit DESA International’s
technical services web site at
www.desatech.com.
AUTO
OFF
ON
Thermopile