SPECIFICATIONS
(V)DVF36NS, (V)DVF36NH
Rating: 33,500 Btu/hr
Gas Type: Natural Gas Only
Ignition: Electronic
Manifold Pressure: 3.5" w.c.
Minimum Inlet Supply Pressure: 5" w.c.
Maximum Inlet Supply Pressure: 10.5" w.c.
Front Orice: #47
Rear Orice: #47
(V)DVF42NS, (V)DVF42NH
Rating: 41,000 Btu/hr
Gas Type: Natural Gas Only
Ignition: Electronic
Manifold Pressure: 3.5" w.c.
Minimum Inlet Supply Pressure: 5" w.c.
Maximum Inlet Supply Pressure: 10.5" w.c.
Front Orice: #42
Rear Orice: #44
(V)DVF36PS, (V)DVF36PH
Rating: 31,000 Btu/hr
Gas Type: Propane/LP Gas Only
Ignition: Electronic
Manifold Pressure: 10" w.c.
Minimum Inlet Supply Pressure: 11" w.c.
Maximum Inlet Supply Pressure: 13" w.c.
Front Orice: #56
Rear Orice: #56
(V)DVF42PS, (V)DVF42PH
Rating: 37,000 Btu/hr
Gas Type: Propane/LP Gas Only
Ignition: Electronic
Manifold Pressure: 10.0" w.c.
Minimum Inlet Supply Pressure: 11" w.c.
Maximum Inlet Supply Pressure: 13" w.c.
Front Orice: #56
Rear Orice: #55
DVF36NS-HA, DVF36NH-HA
Rating: 33,500 Btu/hr
Gas Type: Natural Gas Only
Ignition: Electronic
Manifold Pressure: 3.8" w.c.
Minimum Inlet Supply Pressure: 5" w.c.
Maximum Inlet Supply Pressure: 10.5" w.c.
Front Orice: #47
Rear Orice: #47
DVF42NS-HA, DVF42NH-HA
Rating: 41,000 Btu/hr
Gas Type: Natural Gas Only
Ignition: Electronic
Manifold Pressure: 3.8" w.c.
Minimum Inlet Supply Pressure: 5" w.c.
Maximum Inlet Supply Pressure: 10.5" w.c.
Front Orice: #42
Rear Orice: #44
WIRING DIAGRAM
CONTROL MODULE
BATTERY
RELAY
BATTERY PACK
REMOTE
RECIEVER
VALV E
THTP
TP
TH
Red
Bk
"D"
SIZE
"D"
SIZE
Bn
4 "AA" SIZE
BATTERY
RedBuYlBu BkOgGn
Yl GnBn BkOgBkBk Bn
Bu
Bu
TO J-BOX
ADAPTER
IS
PILOT CONNECTORS
Bk
Red
I
S