18
107105
NATURAL GAS VENT-FREE FIREPLACE SYSTEM
INSPECTING
BURNER
Thermocouple
Pilot Burner
Figure 31 - Correct Pilot Flame Pattern
Thermocouple
Pilot Burner
Figure 32 - Incorrect Pilot Flame Pattern
Check pilot flame pattern and burner flame
pattern often.
PILOT FLAME PATTERN
Figure 31 shows a correct pilot flame pattern.
Figure 32 shows an incorrect pilot flame
pattern. The incorrect pilot flame is not prop-
erly heating the thermocouple. This will cause
the thermocouple to cool. When the thermo-
couple cools, the fireplace will shut down.
If pilot flame pattern is incorrect, as shown
in Figure 32
• turn fireplace off (see To Turn Off Gas to
Appliance)
• see Troubleshooting, pages 20 through 22
Note:
The pilot flame on natural gas units
will have a slight curve, but flame should be
blue and have no yellow or orange color.
TO TURN OFF GAS
TO APPLIANCE
1. Follow steps 1 through 5 under Light-
ing Instructions, page 17.
2. With control knob pressed in, strike
match. Hold match to pilot until pi-
lot lights.
3. Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Now
follow step 8, page 17.
OPERATING
FIREPLACE
Continued
Shutting Off Fireplace
1. Turn control knob clockwise
to the OFF position.
2. Turn off all electric power to the ap-
pliance if service is to be performed.
Shutting Off Burner Only (pilot
stays lit)
Turn control knob clockwise to
the PILOT position.
THERMOSTAT
CONTROL OPERATION
The thermostatic control used on this fire-
place differs from standard thermostats.
Standard thermostats simply turn on and
off the burner. The thermostat used on
this fireplace senses the room tempera-
ture. The thermostat adjusts the amount
of gas flow to the burner. This increases or
decreases the burner flame height. At times
the room may exceed the set temperature.
If so, the burner will shut off. The burner
will cycle back on when room temperature
drops below the set temperature.
The control knob can be set to any heat
level between HI and LO.
Note:
The thermostat sensing bulb mea-
sures the temperature of air near the
fireplace cabinet. This may not always
agree with room temperature (depend-
ing on housing construction, installation
location, room size, open air tempera-
tures, etc.). Frequent use of your fire-
place will let you determine your own
comfort levels.
MANUAL LIGHTING
PROCEDURE
OPERATING BLOWER
OFF
O
N
Auto/Off/On Switch
This blower has three settings: ON, OFF,
and AUTO. In the ON position, the blower
will operate constantly. In the OFF posi-
tion, the blower will not operate. In the
AUTO position, the blower will start when
the thermostat senses a sufficient increase
in firebox temperature.
Note:
Your fireplace and thermostat
blower will not turn on and off at the
same time. The fireplace may run for
several minutes before the blower turns
on. After the heater modulates to the pilot
position, the blower will continue to run.
The blower will shut off after the firebox
temperature decreases.
Note:
It is safe to operate fireplace with
blower turned off. However, the blower
helps distribute heated air from the
fireplace.
Figure 30 - Auto/Off/On Switch