INSPECTING BURNERS
turn heater off (see To Turn Off Gas to Ap-
pliance, page 19.
see Troubleshooting, page 22.
Note: The pilot ame on natural gas units will
have a slight curve, but ame should be blue
and have no yellow or orange color.
BURNER PRIMARY AIR HOLES
Air is drawn into the burner through the holes
in the tting at the entrance to the burner.
These holes may become blocked with dust,
lint or pet hair. Periodically inspect these holes
for any blockage and clean as necessary.
Blocked air holes will create soot.
MAIN BURNER
Periodically inspect all burner ame holes with
the heater running. All slotted burner ame
holes should be open with yellow ame pres-
ent. All round burner ame holes should be
open with a small blue ame present. Some
burner ame holes may become blocked by
debris or rust, with no ame present. If so,
turn off heater and let cool. Remove blockage.
Blocked burner ame holes will create soot.
Figure 26 - Correct Pilot Flame Pattern
Figure 27 - Incorrect Pilot Flame Pattern
Thermocouple
Pilot Burner
Thermocouple
Pilot Burner
CLEANING AND MAINTENANCE
Check pilot ame pattern and burner ame
patterns often.
PILOT FLAME PATTERN
Figure 26 shows a correct pilot ame pattern.
Figure 27 shows an incorrect pilot ame pat-
tern. The incorrect pilot ame is not touching
the thermocouple. This will cause the thermo-
couple to cool. When the thermocouple cools,
the heater will shut down.
If pilot ame pattern is incorrect, as shown
in Figure 27.
WARNING: Turn off heater
and let cool before cleaning.
CAUTION: You must keep
control areas, burner and circu-
lating air passageways of heater
clean. Inspect these areas of
heater before each use. Have
heater inspected yearly by a
qualied service person. Heater
may need more frequent clean-
ing due to excessive lint from
carpeting, bedding material, pet
hair, etc.
WARNING: Failure to keep
the primary air opening(s) of
the burner(s) clean may result in
sooting and property damage.
BURNER INJECTOR HOLDER AND
PILOT AIR INLET HOLE
The primary air inlet holes allow the proper
amount of air to mix with the gas. This pro-
vides a clean burning flame. Keep these
holes clear of dust, dirt, lint and pet hair.
Clean these air inlet holes prior to each
heating season. Blocked air holes will create
soot. We recommend that you clean the unit
every three months during operation and
have heater inspected yearly by a qualied
service person.
We also recommend that you keep the burner
tube and pilot assembly clean and free of dust
and dirt. To clean these parts we recommend
using compressed air no greater than 30 PSI.
Your local computer store, hardware store or
home center may carry compressed air in a
can. If using compressed air in a can, please
follow the directions on the can. If you don’t
follow directions on the can, you could dam-
age the pilot assembly.