FMI CCL3018PTA/NTA Gas Heater User Manual


 
www.fmiproducts.com
124971-01C 21
1. Shut off unit, including pilot. Allow unit to
cool for at least thirty minutes.
2. Inspect burner, pilot and primary air inlet
holes on injector holder for dust and dirt
(see Figure 28).
3. Blow air through the ports/slots and holes
in the burner.
4. Check the injector holder located at the
end of the burner tube again. Remove
any large particles of dust, dirt, lint or pet
hair with a soft cloth or vacuum cleaner
nozzle.
5. Blow air into the primary air holes on the
injector holder.
6. In case any large clumps of dust have now
been pushed into the burner repeat steps
3 and 4.
Clean pilot assembly also. A yellow tip on the
pilot ame indicates dust and dirt in the pilot
assembly. There is a small pilot air inlet hole
about 2" from where the pilot ame comes out
of the pilot assembly (see Figure 29). With the
unit off, lightly blow air through the air inlet
hole. You may blow through a drinking straw
if compressed air is not available.
CLEANING AND MAINTENANCE
Continued
Figure 28 - Injector Holder On Outlet
Burner Tube
Burner Tube
Primary Air
Inlet Holes
Injector Holder
Figure 29 - Pilot Inlet Air Hole
Burner Tube
Pilot Assembly
Pilot Air
Inlet Hole
Ports/Slots
LOGS
If you remove logs for cleaning, refer to
Installing Logs, page 16, to properly replace
logs.
Replace log(s) if broken or chipped (dime-
sized or larger).
MAIN BURNER
Periodically inspect all burner ame holes with
the heater running. All slotted burner ame
holes should be open with yellow ame pres-
ent. All round burner ame holes should be
open with a small blue ame present. Some
burner ame holes may become blocked by
debris or rust, with no ame present. If so,
turn off heater and let cool. Remove blockage.
Blocked burner ame holes will create soot.
SERVICE HINTS
When Gas Pressure Is Too Low
pilot will not stay lit
burners will have delayed ignition
heater will not produce specied heat
for propane/LP units, propane/LP gas sup-
ply may be low
You may feel your gas pressure is too low. If
so, contact your local propane/LP or natural
gas supplier.
TECHNICAL SERVICE
You may have further questions about
installation, operation, or troubleshooting.
If so, contact FMI PRODUCTS, LLC at
1-866-328-4537. When calling please have
your model and serial numbers of your
heater ready.