FMI BVC-36Y Indoor Fireplace User Manual


 
www.fmiproducts.com
122280-01E 5
INTRODUCTION
Models BBM-36(N,P)-TKA, BBM-42(N,P)-
TKA and BBM-50(N,P)-TKA are vented gas
appliances that use an electronic control
valve and electronic ignition system. A FMI
PRODUCTS, LLC venting system and vent
cap are not supplied but are required for
proper operation If a B-type venting system
is installed, transition pipe model BTC-B is
required. See venting instructions beginning
on page 12.
WARNING: This gas appli-



BEFORE YOU BEGIN
Before beginning the installation of your
appliance, read these instructions through
completely.
This FMI PRODUCTS, LLC appliance and
its approved components are safe when
installed according to this installation manual
and are operated as recommended by FMI
PRODUCTS, LLC. Unless you use FMI
PRODUCTS, LLC approved components
tested for this appliance, YOU MAY CAUSE

The FMI PRODUCTS, LLC warranty will
be voided by and FMI PRODUCTS, LLC
disclaims any responsibility for the following
actions:
A) Modication of the appliance or any of the
components.
B) Use of any component part not approved
by FMI PRODUCTS, LLC in combination
with this appliance.
C) Installation and/or operation in a manner
other than instructed in this manual.
D) The burning of anything other than the
type of gas approved for use in this gas
appliance.
The installation must conform with local
codes or, in the absence of local codes, with
the current National Fuel Gas Code, ANSI
Z223.1/NFPA 54.
WARNING: Installation of this


NOTICE: This appliance is not

source of heat.
CAUTION: Do not connect
-



The appliance and it’s individual shutoff valve
must be disconnected from the gas supply
piping system during any pressure testing of
that system at test pressures in excess of 1/2
psig (3.5 kPa).
The appliance must be isolated from the gas
supply piping system by closing its individual
manual shutoff valve during any pressure
testing of the gas supply piping system at
test pressures equal to or less than 1/2 psig
(3.5 kPa).
For the purpose of input adjustment two
pressure taps (for IN and OUT pressures)
are provided on the gas control valve for test
gauge connections to the appliance.