FMI BV36(B) Indoor Fireplace User Manual


 
www.fmiproducts.com
123492-01E8
IMPORTANT: Vent-free gas log heaters add
moisture to the air. Although this is benecial,
installing firebox in rooms without enough
ventilation air may cause mildew to form from
too much moisture. See Air for Combustion
and Ventilation, page 5.
IMPORTANT: Make sure rebox is level. If re-
box is not level, log set will not work properly.
Note: Your rebox is designed to be used in zero
clearance installations. Wall or framing material can
be placed against any exterior surface on the rear,
sides, top or bottom of your rebox, except where
standoff spacers are integrally attached. If standoff
spacers are attached to your rebox, these spac-
ers can be placed directly against wall or framing
materials. Use the dimensions shown for rough
opening to create the easiest installation.
Use dimensions shown for rough openings
to create the easiest installation (see Built-In
Firebox Installation, page 9).
INSTALLATION CLEARANCES
WARNING: Maintain the



Carefully follow these instructions. This will
ensure safe installation.


A. Clearances from the side of fireplace
cabinet to any combustible material and
wall should follow diagram in Figure 4.
Example: The face of a mantel, bookshelf,
etc. is made of combustible material and
protrudes 3
1
/
2
" from the wall. This com-
bustible material must be 4" from the side
of the replace cabinet (see Figure 4).
B. Clearances from the top of rebox opening
to ceiling should not be less than 42".
C. When rebox is installed on carpeting or
other combustible material, other than
wood ooring, rebox should be installed
on a metal or wood panel extending the
full width and depth of enclosure.
D. Clearances from bottom of rebox to the
oor is 0".
These reboxes can be installed as freestanding
units against a wall with the approved, optional
cabinet mantels (see Accessories, page 14) or as
a built-in unit. Clearances are the same for either
installation method.
INSTALLATION
Continued
Figure 4 - Minimum Clearance for
Combustible to Wall
*Minimum 16" from Side Wall
*
-

Example
Mantel Clearances for Built-In Installation
If placing custom mantel above built-in rebox,
you must meet the minimum allowable clear-
ance between mantel shelf and top of rebox
opening shown in Figure 5, page 9. These are
the minimum allowable mantel clearances for
a safe installation. Use larger clearances wher-
ever possible to minimize the heating of objects
and materials placed on the mantel.
CAUTION: Do not allow
    



-



-


Follow all minimum clearances

NOTICE: If your installation does
not meet the minimum clearances
shown, you must do one of the

 -

 