www.fmiproducts.com
115386-01D14
OPTIONAL GAS LINE INSTALLATION
Continued
WARNING: If the replace
has been used for wood burn-
ing, rebox and chimney must
be cleaned of soot, creosote and
ashes be a qualied chimney
cleaner. Creosote will ignite if
heavily heated.
OPERATION AND MAINTENANCE
Figure 23 - Glass Doors
Cleaning Glass
Clean glass with any commercial glass
cleaner or soap and water. Do not use any
abrasive material to clean the glass. Do not
clean glass with any cool water if glass is still
hot from re and smoke.
A gas line or gas log lighter may be installed
for the purpose of installing a vented or vent-
free decorative gas appliance incorporating an
automatic shutoff device and complying with
the Standard for Decorative Gas Appliances
for Installation in Vented Fireplaces, ANSI
Z21.60 or American Gas Association draft
requirements for Gas Fired Log Lighters for
Wood Burning Fireplaces, Draft NO. 4 dated
August, 1993.
If you wish to install an unvented (vent-free)
gas log set, only unvented gas log sets which
have been found to comply with the standard
for unvented room heaters, ANSI Z21.11.2 are
to be installed in this replace.
WARNING: When using
a decorative vented gas log,
damper must be removed or
permanently locked in fully open
position and glass doors must
be in fully open position.
GLASS DOORS
Glass doors are optional with this replace.
When replace is in operation, doors must be
fully opened or fully closed position only or a
re hazard may be created (see Figure 23).
A replace equipped with glass doors oper-
ates much differently than a replace with an
open front. A replace with glass doors has a
limited amount of air for combustion. Exces-
sive heat within replace can result if too large
a re is built or if combustion air gate is not
completely open.
The following tips should be used to assure
that both fireplace and glass door retain
their beauty and function properly. Both the
ue damper and glass doors must be fully
opened before starting a re. This will provide
sufcient combustion air and maintain safe
temperatures in rebox.
IMPORTANT: The glass must be allowed
to warm slowly and evenly. Tempered glass
will withstand a gradual temperature rise to
550° F, which is more than a normal re will
generate. Such materials as pitch/wax laden
logs, very dry mill end lumber and large
amounts of paper or cardboard boxes can
create an excessively hot re and should not
be burned in this replace. Always keep re
back from doors and never allow ames to
contact glass.
WARNING: Fireplaces
equipped with glass doors
should be operated only with
doors fully opened or doors fully
closed. Doors, if left partly open,
may draw gas and ame out of
the replace opening creating
risks of both re and smoke.
Doors Fully Closed
Doors Fully Opened
Fireplace Front
Fireplace Front