Thermal
Temperature Range............................................-10 to 350 °C (14 to 662 °F)
Detector Type ..................................................... 80 x 60 thermal element focal plane array (FPA)
Accuracy.............................................................± 2 °C or 2 % (whichever is greater)
Repeatability....................................................... ± 1 % or ± 1 °C (± 2 °F) whichever is greater
NETD (Thermal Sensitivity) ................................ 200 mK
Temperature Indication....................................... 0.1 °C or 0.2 °F
Optical
Field of View (FOV)............................................. Rectangular. 20° Horizontal x 15° Vertical
Minimum Diameter..............................................8.1 mm (0.32 in) at 61 cm (24 in)
Optical Resolution (D:S) ..................................... 75:1 or better
Spectral Range................................................... 7.5 to 14 microns
Target Sighting....................................................Single Laser (IEC 825/93 Class II, FDA LFR 1040.10 Class II
Instantaneous Field of View................................4.4 mrad
Controls
Focus.................................................................. 61 cm (24 in) to infinity
Temperature Scale ............................................. °C or °F selectable
Palettes............................................................... Original, Gray, Rainbow (default), Ironbow, Gray Reverse
Measurement Modes.......................................... Automatic or Manual
LCD Backlight..................................................... Bright/Dim selectable
Operational
Adjustable Emissivity...........................................10 to 1.00 by 0.01
Liquid Crystal Display ......................................... 70.5 mm (2.78 in) x 53.5 mm (2.1 in)
Reflected Background Temperature................... -50 to 905 °C (-58 to 1661 °F)
Ambient Operating Temperature ........................ 0 to 50 °C (32 to 122 °F)
Relative Humidity................................................ 10 to 90 % noncondensing
Storage Temperature..........................................-25 to 70 °C (-13 to 158 °F) without batteries
Storage Capacity ................................................ 50 images
Electrical
Power..................................................................Rechargeable battery pack (included)
Battery Life..........................................................Minimum 3 hours continuous use
Battery Charge Time...........................................2 hours in the Imager, 1 hour in the external charger (or until the green
LED turns on)
Data Transfer...................................................... USB interface, transfer time 25 sec for 50 images
Storage Device ................................................... Flash Memory