Fluke 568 Thermostat User Manual


 
Infrared Thermometers
User Replaceable Parts and Accessories
19
Recommended Temperature Probes
See Table 6 for a list of recommended temperature probes.
Table 6. Recommended Temperature Probes
Probe Usage
80PK-1
The general purpose bead probe is an alternative, for quick, accurate surface
temperatures and air temperatures within ducts, vent temperatures.
80PK-8
Pipe clamp probes (2) are essential for tracking continuously changing
temperature differentials on hydronic tubing and pipe loops, and good for quick,
accurate refrigerant temperatures.
80PK-9
The insulation piercing probe provides a sharp tip to pierce pipe insulation and flat
probe tip for good surface thermal contact, air temperatures within ducts, and vent
temperatures.
80PK-11
The Velcro pipe probe is a convenient way to attach a thermocouple to a pipe
while keeping hands free.
80PK-25
The piercing probe is the most versatile option. Good for checking air temperature
in ducts, surface temperature under carpets/pads, liquids, thermometer wells, vent
temperatures, and for penetrating pipe insulation.
80PK-26
The tapered probe is a good general-purpose gas and surface probe, with a good
length and low mass tip casing for faster reaction to surface and air temperatures.