5
IF THIS SMOKE ALARM SOUNDS
RESPONDING TO AN ALARM
During an alar
m, you will hear a loud, repeating horn pattern:
3 beeps, pause, 3 beeps, pause.
•
If the unit alarms and you are not testing the unit, it is warning you of a
potentially danger
ous situation that requires your immediate attention.
NEVER ignore any alarm. Ignoring the alarm may result in injury or
death.
• Never disconnect the AC power to quiet an unwanted alarm.
Disconnecting the power disables the Alar
m so it cannot sense
smoke. This will r
emove your protection. Instead, open a window or
fan the smoke away from the unit. The Alarm will reset automatically.
• If the unit alarms get everyone out of the house immediately.
•
ELECTRICAL SHOCK HAZARD: Attempting to disconnect the power
connector from the unit when the power is on may result in electrical
shock, serious injury or death.
When an inter
connected system of AC powered units is in alarm, the alarm
indicator light on the unit(s) that initiated the alarm will blink rapidly. It will
r
emain OFF on any remaining units.
If the unit alarms, get everyone out of the dwelling immediately
.
If the unit alarms and you are certain that the source of smoke is not a fire—
cooking smoke or an extr
emely dusty furnace, for example—open a nearby
window or
door and fan the smoke away from the unit (Use the Silence Feature
to silence the Alarm). This will silence the alarm, and once the smoke clears the
unit will r
eset itself automatically.
WHAT TO DO IN CASE OF FIRE
• Don’t panic; stay calm. Follow your family escape plan.
• Get out of the house as quickly as possible. Don’t stop to
get dr
essed or collect anything.
•
Feel doors with the back of your hand before opening them.
If a door is cool, open it slowly. Don’t open a hot door. Keep doors
and windows closed, unless you must escape through them.
• Cover your nose and mouth with a cloth (preferably damp).
Take short, shallow breaths.
• Meet at your planned meeting place outside your home,
and do a head count to make sure everybody got out safely.
• Call the Fire Department as soon as possible from outside.
Give your address, then your name.
• Never go back inside a burning building for any reason.
• Contact your Fire Department for ideas on making your home safer.
Alarms have various limitations. See "Limitations of Smoke Alarms" for
details.
USING THE SILENCE FEATURE
The Silence Feature can temporarily quiet an unwanted alarm for up to 15
minutes.
The Silence Feature does not disable the unit—it makes it temporarily
less sensitive to smoke. For your safety
, if smoke ar
ound the unit is
dense enough to suggest a potentially dangerous situation, the unit will
stay in alarm or may re-alarm quickly. If you do not know the source of
the smoke, do not assume it is an unwanted alarm. Not responding to an
alarm can result in property loss, injury, or death.
To silence Smoke Alarms in an interconnected series:
1. To silence multiple alarms in an interconnected series, you must press the
Test/Silence button on the unit(s) that triggered the alarm.
2. Once you activate the Silence feature, the Red LED will continue to flash
rapidly
.
3.
Pr
essing the T
est/Silence button when in silence will restart the silence
timer.
The Silence Featur
e on these units can temporarily quiet an unwanted alarm
for up to 15 minutes. T
o use this featur
e, press the Test/Silence button on the
cover.
If the unit will not silence and no heavy smoke is present, or if it
stays in silence mode continuously, it should be replaced immediately.
WIRELESS OPERATION
First Alert
®
ONELINK
TM
Technology is the easy, cost-effective way to provide
your family with whole-home safety. All ONELINK
TM
Alarms communicate with
each other without wires or connectors. When one Alarm sounds, they all
sound. This provides your family with an earlier warning of potential danger,
and gives you more time to react.
The communication distance (range) between any two ONELINK
TM
Alarms is
typically 50 feet (15 meters) inside of a home. Some features of a home, such
as the number of floors, number/size of rooms, furniture and types of building
materials used may reduce the range of the Alarms. Examples include:
suspended ceilings, ductwork, large metallic appliances (refrigerators) and
metal studs. A feature of ONELINK
TM
Alarms is that they operate as a mesh
network. All Alarms will repeat any alarm signal that is received to all other
ONELINK
TM
Alarms. Interference from structural conditions can be overcome
by adding additional Alarms to route the wireless signal around obstructions.
• The range and proper operation of any wireless device will vary
depending on its surroundings. It is very important that each
Alarm is tested individually before and after installation to make
sure that all Alar
ms r
espond properly.
• The ONELINK
TM
Alarms are not to be used outdoors or to transmit
between buildings. The Alar
ms will not communicate pr
operly
under these conditions.
• Metal objects and metallic wallpaper may interfere with signals
from wireless Alarms. Alarms should be tested after changes to
your home such as remodeling, moving furniture, and with metal
doors opened and closed.
Your First Alert
®
ONELINK
TM
Smoke Alarm will automatically communicate
potential fires with all other First Alert
®
ONELINK
TM
Smoke Alarms.
FCC NOTICE: This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This device may not
cause harmful interfer
ence, and (2) this device must accept any interfer
ence
r
eceived, including interference that may cause undesired operation.
FCC ID: M7U5201L
Changes or modifications not expressly approved by BRK Brands, Inc.
could void the user’s authority to operate the equipment.
SILENCING THE LOW BATTERY WARNING
This silence feature can temporarily quiet the low battery warning “chirp” for
up to 8 hours. Y
ou can silence the low battery warning “chirp” by pressing the
Test/Silence button on the alarm cover.
Once the low battery warning “chirp” silence feature is activated, the unit
continues to flash the Green light twice a minute for 8 hours. After 8 hours, the
low battery “chirp” will r
esume.
Replace the batteries as soon as possible;
this unit will not operate without battery power!
T
o deactivate this featur
e:
Pr
ess the T
est/Silence button again. The unit will
go into Test Mode and the low battery warning will resume (LED flashes and
unit sounds “chirp” once a minute).
UNDERST
ANDING THE INDICATOR LIGHTS
AND ALARM HORN PATTERNS
NOTE: When power is applied, unit(s) may alar
m momentarily.
*
When any Smoke Alarm in an inter
connected series triggers an alarm, its
red LED will flash rapidly. The red LEDs will remain OFF on any remaining
alarms in the series. This featur
e helps responders identify which unit(s)
trigger
ed the alarm.
AC Power
All Models
DC Power
Normal Operation Constant Green LED
No Audible Alarm
Green LED Off
No Audible Alarm
T
est Condition
Constant Gr
een LED
Rapidly Flashing
Red LED
Audible Alarm
Gr
een LED Off
Rapidly Flashing
Red LED
Audible Alarm
Silence Mode Rapidly Flashing
Red LED
Rapidly Flashing
Red LED
Alar
m Condition*
(Initiating Unit)
Constant Gr
een LED
Rapidly Flashing
Red LED
Audible Alarm
Gr
een LED Off
Rapidly Flashing
Red LED
Audible Alarm
Low Battery Alarm “chirp’’ approx.
once/minute
Alarm “chirp’’ approx.
once/minute
Malfunction 3 rapid “chirps”
every
minute; LED flashes
approx. once a minute
3 rapid “chirps”
every
minute; LED flashes
approx. once a minute