First Alert FA168CP-CN Home Security System User Manual


 
5
67
RF XMTR LOW BAT REPORT CODE
| [00] See box on previous page.
UL: must be enabled if wireless devices are used
68
CANCEL REPORT CODE
| [00] See box on previous page.
RESTORE REPORT CODES (
70 –
76)
70
ALARM RESTORE RPT CODE
[0] See box on previous page.
71
TROUBLE RESTORE RPT CODE
| [00] See box on previous page.
72
BYPASS RESTORE RPT CODE
| [00] See box on previous page.
73
AC RESTORE RPT CODE
| [00] See box on previous page.
74
LOW BAT RESTORE RPT CODE
| [00] See box on previous page.
75
RF XMTR LO BAT RST RPT CODE
| [00] See box on previous page.
UL: must be enabled if wireless devices are used
76
TEST RESTORE RPT CODE
| [00] See box on previous page.
OUTPUT AND SYSTEM SETUP (
77 –
93)
77
DAYLIGHT SAVINGS TIME
START\END MONTH
| [4][10]
0 = Disabled
1-12 = January-September (1 = Jan, 2 = Feb, etc)
#+10 = October; #+11 = November; #+12 = December
78
DAYLIGHT SAVINGS TIME
START\END WEEKEND
| [1][5]
0 = disabled, 1 = first, 2 = second, 3 = third
4 = fourth, 5 = last, 6 = next to last, 7 = third to last
84
AUTO STAY ARM
[0]
0 = no, 1 = partition 1 only
2 = partition 2 only, 3 = both partitions
85
CROSS ZONE TIMER
This option not for use in UL installations.
[0]
0 = 15 seconds 6 = 2-1/2 min #+12 = 8 min
1 = 30 seconds 7 = 3 min #+13 = 10 min
2 = 45 seconds 8 = 4 min #+14 = 12 min
3 = 60 seconds 9 = 5 min #+15 = 15 min
4 = 90 seconds #+10 = 6 min
5 = 2 minutes #+11 = 7 min
(assign cross zones on zone list 4, with *81 Menu mode)
86
CANCEL VERIFY
[0]
0 = no, 1 = yes
87
MISC. FAULT DELAY TIME
(used with Configurable Zone Types “digit 6”)
[0]
0 = 15 seconds 6 = 2-1/2 min #+12 = 8 min
1 = 30 seconds 7 = 3 min #+13 = 10 min
2 = 45 seconds 8 = 4 min #+14 = 12 min
3 = 60 seconds 9 = 5 min #+15 = 15 min
4 = 90 seconds #+10 = 6 min
5 = 2 minutes #+11 = 7 min
UL: may only be used on non-burglar alarm/ non-fire alarm
zones when used in fire and/or UL burglar alarm installation
89
EVENT LOG FULL REPORT CODE
| [00]
See box on previous page for report code entries.
90
EVENT LOG ENABLES
[3]
NOTE
:
System messages are
logged when any non-zero
selection is made.
0 = None; 1 = Alarm/Alarm Restore
2 = Trouble/Trouble Restore;
4 = Bypass/Bypass Restore;
8 = Open/Close.
Example:
To select “Alarm/Alarm
Restore”, and “Open/Close”, enter 9 (1 + 8); To select
all, enter #15.
91
OPTION SELECTION
[8]
0 = None
1 = Local Lockout 4 = AAV UL: do not use AAV
2 = Sounder Delay 8 = Exit Delay Restart
E.g. (multiple choice): for AAV (4) plus Exit Delay restart
(8) enter # + 12; for all (1 + 2 + 4 + 8), enter # + 15.
92
PHONE LINE MONITOR ENABLE
UL: see Inst. Instructions for requirements
[0,0]
Digit 1:
: 0 = disabled, 1-15 = 1 min - 15 min
(#+10 = 10 min; #+11 = 11 min; #+12 = 12 min;
#+13 = 13 min; #+14 = 14 min; #+15 = 15 min)
Digit 2
:
0 = Keypad display when line is faulted
1 = Keypad display plus keypad trouble sound
2 = Same as “1”, plus programmed output device
STARTS. If either partition is armed, external sounder
activates also.
NOTE:
Output Device must either be
programmed to be STOPPED in field
80 or
STOPPED by Code + # + 8 + output number.
93
No. OF REPORTS IN ARMED PERIOD
PER ZONE (Swinger Suppression)
[0]
0 = Unlimited Reports; 1 = 1 report; 2 = 2 reports
UL: must be “0”