First Alert FA168C Home Security System User Manual


 
4
NOTE:
Entry of a number other than one specified will give unpredictable results.
For fields *43-*46:
Enter 0–9; #+11 for B; #+12 for C; #+13 for D; #+14 for E; #+15 for F. Enter
[
]
as the fourth digit if a 3-digit account number (for 3+1 dialer
reporting format) is used. Enter 0 as the first digit of a 4-digit account number for Nos. 0000-0999. Exit field by pressing
(and press next field number) if only 3
digits are used. E.g., For Acct.
B234
, enter: #+11| 2 | 3 | 4
43
PARTITION 1 PRIMARY SUBS. ACCT. No.
| | | [FFFF]
See box above for entries. To clear entries
from field, press
*
43
*.
44
PARTITION 1 SECONDARY SUBS. ACCT. No.
| | | [FFFF]
See box above for entries. To clear entries
from field, press
*
44
*
.
45
PARTITION 2 PRIMARY SUBS. ACCT. No.
| | | [FFFF]
See box above for entries. To clear entries
from field, press
*
45
*
.
46
PARTITION 2 SECONDARY SUBS. ACCT. No.
| | | [FFFF]
See box above for entries. To clear entries
from field, press
*
46
*
.
47
PHONE SYSTEM SELECT
[1]
If Cent. Sta.
IS NOT
on a WATS line:
0=Pulse Dial; 1=Tone Dial;
if Cent. Sta.
IS
on
a WATS line:
2 = Pulse Dial ; 3 = Tone Dial
48
REPORT FORMAT
[70]
primary secondary
0 = 3+1, 4+1 ADEMCO L/S STANDARD
1 = 3+1, 4+1 RADIONICS STANDARD
2 = 4+2 ADEMCO L/S STANDARD
3 = 4+2 RADIONICS STANDARD
6 = 4+2 ADEMCO EXPRESS
7 = ADEMCO CONTACT ID® REPORTING
8 = 3+1, 4+1 ADEMCO L/S EXPANDED
9 = 3+1, 4+1 RADIONICS EXPANDED
49
SPLIT/DUAL REPORTING
[0]
0 = Disable (Backup report only)
Primary Phone No.
Second
Phone No.
1 = Alarms, Restore, Cancel Others
2 = All except Open/Close, Test Open/Close,
Test
3 = Alarms, Restore, Cancel All
4 = All except Open/Close, Test All
5 = All All
50
15 SEC DIALER DELAY (BURG)
[0]
0 = no UL: must be “0”
; 1 = yes
53
SESCOA/RADIONICS SELECT
[0]
0 = Radionics (0-9, B-F)
1 = SESCOA (0-9 only reporting)
Select “0” for all other formats.
54
DYNAMIC SIGNALING DELAY
[0]
Delay selectable from 0 to 225 secs in 15-sec
increments.
0 = no delay (both signals sent), 1 = 15 secs,
2 = 30 secs, etc. UL: must be “0”
55
DYNAMIC SIGNALING PRIORITY
[0]
0 = Primary Dialer first; 1 = Long Range Radio
first.
TO PROGRAM SYSTEM STATUS, & RESTORE REPORT CODES (
59 –
76, &
89):
For 3+1 or 4+1 Standard Format:
Enter a code in the
first
box: 1–9, #+10 for 0, #+11 for B, #+12 for C, #+13 for D, #+14 for E, #+15 for F.
A 0 (
not
#+10) in the
first
box will disable a report. A 0 (
not
#+10) in the
second
box will result in automatic advance to the next field.
For Expanded or 4+2 Format:
Enter codes in
both
boxes (1st and 2nd digits) for 1–9, 0, or B–F, as described above.
A 0 (
not
#+10) in the
second
box will eliminate the expanded message for that report. A 0 (
not
#+10) in
both
boxes will disable the report.
For Ademco Contact ID® Reporting:
Enter any digit (other than 0) in the
first
box, to enable zone to report (entries in the
second
boxes are ignored).
A 0 (
not
#+10) in the
first
box disables the report.
UL: see installation instructions for requirements
SYSTEM STATUS REPORT CODES (
59–
68)
59
EXIT ERROR REPORT CODE
[0] See box above.
60
TROUBLE REPORT CODE
| [00] See box above.
61
BYPASS REPORT CODE
| [00] See box above.
62
AC LOSS REPORT CODE
| [00] See box above.
63
LOW BAT REPORT CODE
| [00] See box above.
64
TEST REPORT CODE
| [00] See box above. Use Scheduling mode to set periodic test reports.
65
OPEN REPORT CODE
[0,0,0] See box above.
Part. 1 Part. 2 Common
66
ARM AWAY/STAY RPT CODE
[0,0,0,0,0,0]
See box above.
Away Stay Away Stay Away Stay
Part. 1 Part. 2 Common