First Alert FA168C Home Security System User Manual


 
– 13 –
(QWU\([LW'HOD\V
&RQWLQXHG
([LW$ODUPV
Whenever you arm the system, the exit delay begins. If an entry/exit door or interior
zone is faulted when the exit delay ends (e.g., exit door left open), the system sounds
an alarm and starts the entry delay timer. If you disarm the system before the entry
delay ends, the alarm sound stops and the message "CANCELED ALARM" or "CA" is
displayed on the keypad, along with a zone number indicating the faulted zone. No
message is sent to the Central Monitoring Station.
To clear the exit alarm condition, the open zone must be made intact; to clear the
display, enter your code plus OFF.
If you do not disarm the system before the entry delay ends, and an entry/exit door or
interior zone is still open, the alarm sound continues and an "exit alarm" message is
sent to the Central Monitoring Station. The message ""EXIT ALARM" or "EA" is
displayed on the keypad, along with a zone number indicating the faulted zone. To
stop the alarm, the system must be disarmed (your code plus OFF); to clear the
display, enter your code plus OFF a second time.
An “exit alarm” also results if an entry/exit door or interior zone is faulted within two
minutes after the end of the exit delay.
Your system may have been programmed for this feature to minimize false alarms sent to the Central
Monitoring Station. Ask your installer if "Exit Alarm" is active in your system. If so, check this box.
&KHFNLQJ)RU2SHQ=RQHV
8VLQJWKH>@.H\
B
efore arming your system, all protected doors, windows and other protection zones
must be closed or bypassed, otherwise the keypad will display a "Not Ready"
message.
Use the READY
key to display all faulted zones, making it easier for you to identify
and secure any open zone.
1. Press [
] (do not enter code first) to display faulted
zones
.
2. Secure or bypass the zones displayed.
3.
The keypad’s READY indicator lights when all
protection zones have been either closed or bypassed.
4. Arm the system as desired.
Alpha Display:
Fixed-Word Display:
Zone no. and “NOT READY”