STEP BY STEP GUIDE TO PROGRAMMING
THIS ALARM
FOR FIRST TIME AND WHEN CHANGING BATTERIES
Action:
1. Insert batteries (2, AA batteries).
Alarm Will Say:
“Welcome, First Alert Carbon
Monoxide Alarm.”
“No location programmed” if first
time
or “[Location, example:
“Basement”] location pr
ogrammed”
when changing batteries.
“T
o select location, press and hold
test button now.”
2.
Press & Hold Test Button if you
would like to program the location
or change the location of the
Alarm. Release button after Alarm
responds.
“T
o save location, press and hold test
button after location is heard.” Alarm
will speak list of locations (see
below).
3.
After you hear the location of where
you are placing the Alarm, Press &
Hold the T
est Button.
“[Location, example: “Basement”]
location saved.”
If no location is chosen:
“No location saved.”
Y
our Alarm has now been programmed for the location of your choice.
A
vailable locations:
Basement
Kitchen Child’s Bedroom
Living Room Dining Room Master Bedroom
Family Room
No Location Guest Bedroom
Of
fice Hallway Utility Room
NOTE: Steps 1 through 3 need to be completed within two minutes. If
mor
e than two minutes pass, the Green power LED will stop blinking.
Simply open the batter
y drawer of the second Alarm and repeat
steps 1 through 3.
1. Insert the batteries into the battery
drawer of the
next Alarm.
DO NOT CLOSE THE DRA
WER.
2. Press and hold the test button and
then close the battery drawer.
3.
Once you hear the unit chirp,
r
elease the test button.
The Green power LED will start
to blink indicating the ONELINK
®
Alarm is waiting for pr
ogram data
from one of the other setup ONELINK
®
Alarms.
4. Press and hold the test button on the first Alarm, until the second Alarm
chirps and its Gr
een power LED stops blinking. Then release the test button.
5.
If you have purchased the hardwired battery back-up ONELINK
®
Alarm,
you can now connect the hardwired Alarm by installing the three-wire
connector on the ceiling to the Alarm.
6.
Repeat steps 1-5 for additional ONELINK
®
Alarms.
You have now successfully linked your new ONELINK
®
Alarms. To add
additional Alarms at a later time, follow steps 1 through 5.
ADDING AND LINKING ADDITIONAL ONELINK
®
ALARMS
WHAT YOU WILL SEE AND HEAR WITH THIS ALARM
Under Nor
mal Operations
Voice: Silent
Horn: Silent
Power LED: Flashes Green once/minute
When You Test the Alarm
Voice:
Testing.”
Horn: 4 fast beeps, pause, 4 fast beeps;
Voice: “Warning, evacuate carbon monoxide in [Location, example:
“Basement”]. Evacuate.” Pause. “Highest carbon monoxide level
was [CO level example: _0_
ppm]”.
CO LED: Flashes Red in sync with the horn pattern
If Battery Becomes Low or is Missing
Voice:
“Replace battery in [Location, example “Basement”].”
Repeated every 5 hours
Horn: chirps once a minute
Power LED: Flashes Green On for 2 seconds/Off for 2 seconds.
Low Battery Latch is now engaged.
If Alarm is Not Operating Properly (MALFUNCTION SIGNAL)
Voice: “Detector error in [Location, example “Basement”], please see
manual.” Repeated every 5 hours
Horn: Three rapid chirps every minute
CO LED: Flashes approximately once a minute
Alarm Levels of CO are Detected
Horn: 4 fast beeps, pause, 4 fast beeps, pause*
Voice:
“Warning, evacuate carbon monoxide in [Location, example:
“Basement”]. Evacuate.” Pause. “Highest carbon monoxide level
was [CO level example: ___ ppm]”.
Horn: 4 beeps, pause, 4 beeps, pause repeating 2 times followed by
Voice Warning above.
CO LED: During Alarm: Flashes Red in sync with the hor
n pattern. After
Alarm: Flashes Red On for 2 seconds/Off for 2 seconds. CO
Alarm Latch is now engaged.
*NOTE: If unit goes into CO alarm, the r
egular 4 beeps-brief pause cycle will
repeat for fifteen minutes. After fifteen minutes, the pause will increase to one
minute.
CO Alarm is Silenced
Horn: Off
CO LED: Flashes Red
4