Fireboy- Xintex, LTD MA2 FE-241 Fire Extinguisher User Manual


 
13
3. Push the cable end through the hole on the cylinder manifold far enough
to allow the flexible strand to be bent.
4. Place “S” hook through the hole in the MA lever.
5. Gently pull cable sheath back into manifold, aligning the groove in sheath
with slot in the manifold.
6. Insert the wire retaining clip provided around the groove in the cable
sheath through the slot in the manifold securing the cable.
WARNING:
With the “S” hook attached to the MA lever, and the wire retaining clip
not properly installed, any pull on the cable exceeding 20lbs may actuate
the fire extinguisher
Never install, remove or service the cable when the fire extinguisher is
not securely mounted in its brackets
Always wear eye protection while servicing any component of your
Fireboy fire extinguisher
Operation of Fireboy Fire Extinguisher
Automatic operation of CG2 and MA2 systems
Actuation of a Fireboy fire extinguisher occurs at 175°F (79°C) and is
entirely dependent on the intensity of the fire
Manual operation of MA2 Systems
1. Do not wait for automatic actuation.
2. Close all hatches leading to the protected compartment.
3. Shutdown all forced ventilation devices, engines, generators and
electrical systems.
4. Remove the safety pin from the “FIRE” T-handle, and pull firmly.
Signs of actuation