95% AFUE, ALL-POSITION, TWO-STAGE, VARIABLE SPEED GAS FURNACE
Model Number FV95A0543A FV95A0723A FV95A0905A FV95A1085A
Gas Controls
Minimum Inlet Pressure (in. wc) 5 5 5 5
Maximum Inlet Pressure (in. wc) 13.6 13.6 13.6 13.6
Gas Inlet (Inches) 1/2 1/2 1/2 1/2
LP Convertible Yes Yes Yes Yes
Low Nox Capability Standard Standard Standard Standard
Ignition Device
Type Hot Surface Hot Surface Hot Surface Hot Surface
General Component
Limit Control SPST SPST SPST SPST
Transformer (V.A.) 40 40 40 40
Primary Heat Exchanger
Number of Burners 3 4 5 6
Heat Exchanger Type Tubular Tubular Tubular Tubular
Number of Tubes 3 4 5 6
Approximate BTUs / Tube HF 18,000 18,000 18,000 18,000
Tube Diameter (Inches) 1.75 1.75 1.75 1.75
Number of Passes 3 3 3 3
Secondary Heat Exchanger
Heat Exchanger Type 29-4C SS 29-4C SS 29-4C SS 29-4C SS
Width / Depth (Inches) 12 / 16.5 15 / 16.5 17 / 16.5 19 / 16.5
Number of Circuits 21 30 38 45
Fin Type Aluminum Aluminum Aluminum Aluminum
FPI 7 7 7 7
Number of Rows 3 3 3 3
Physical Data
Cabinet Information
Cabinet Size (W) (Inches) 17.5 20.5 20.5 24.5
Cabinet Size (H) (Inches) 40 40 40 40
Cabinet Size (D) (Inches) 29 29 29 29
Plenum Dimensions
Width (Inches) 16.5 19.5 19.5 24
Depth (Inches) 19 19 19 19
Return Air Opening - Side
Height (Inches) 14 14 14 14
Depth (Inches) 22 22 22 22
Return Air Opening - Bottom
Width (Inches) 16 19 19 23
Depth (Inches) 19 19 19 19
Packaging
Package (W) (Inches) 18.5 21.5 21.5 25.5
Package (H) (Inches) 41 41 41 41
Package (D) (Inches) 30 30 30 30
Packaged Weight (lbs)
Product Specifications
Note: 2" connections provided for combustion air intake and vent on all sizes.
3
Specifications subject to change without notice.
145 160 175 210