Fedders FV95A Series Furnace User Manual


 
95% AFUE, ALL-POSITION, TWO-STAGE, VARIABLE SPEED GAS FURNACE
Model Number FV95A0543A FV95A0723A FV95A0905A FV95A1085A
Position All-Position All-Position All-Position All-Position
Electrical Characteristics
Volts 120 120 120 120
Hertz 60 60 60 60
Phase 1 1 1 1
Operating Voltage Range (Min-Max) 102 - 132 102 - 132 102 - 132 102 - 132
Max Fuse or CKT Breakers (Amps) 15 15 15 15
Minimum Wire Size 14 14 14 14
Performance Data - Input BTUH
Low 35,100 46,800 58,500 70,200
High 54,000 72,000 90,000 108,000
Performance - Cooling Data
Furnace Cooling Category (Tons) 1.5 - 3 1.5 - 3.5 2.5 - 5 2.5 - 5
AFUE%
Direct Vent (2 pipe) Upflow 95 95 95 95
Direct Vent (2 pipe) Horizontal / Downflow 94 94 94 94
Min. Output Capacity
Direct Vent (2 pipe) - Low Upflow 33,345 44,460 55,575 66,690
Direct Vent (2 pipe) - Low Horizontal / Downflow 32,994 43,992 54,990 65,988
Direct Vent (2 pipe) - High Upflow 51,300 68,400 85,500 102,600
Direct Vent (2 pipe) - High Horizontal / Downflow 50,760 67,680 84,600 101,520
Certified Temperature Rise
Temperature Rise (°F ) Low 35 - 65 35 - 65 35 - 65 35 - 65
Temperature Rise (°F ) High 35 - 65 35 - 65 35 - 65 35 - 65
Airflow at 0.5" Static
Airflow CFM Approx
Low Heating
T 50
°F
618 823 1,029 1,235
Airflow CFM Approx High Heating T 50°
F
950 1,267 1,583 1,900
Airflow Cooling Max 1,200 1,400 1,800 1,900
Component Data
Blower Information
Blower Diameter & Width (Inches) 11 x 7 11 x 7 11 x 10 11 x 10
Variable Speed Motor 3/4 hp - ECM 3/4 hp - ECM 1 hp - ECM 3/4 hp - ECM
Motor Speed Variable Variable Variable Variable
Motor Full Load Amps 7.7 9.6 12.8 9.6
Inducer Draft Blower
Type 2-Speed 2-Speed 2-Speed 2-Speed
Product Specifications
2