Product Specifications
2
Specifications subject to change without notice.
NOTES:
1. Values based on Natural Gas usage
2. Important: It is required to size fuses and wires properly and make electrical connections
in accordance with the National Electrical Code and/or all existing local codes
PRODUCT SPECIFICATIONS
Model Number FV80A070-4A FV80A085-4A FV80A115-5A
PERFORMANCE RATINGS
I
nput - High Fire (Btu) - Second Stage
1
6
8,000
8
5,000
1
15,000
Output - High Fire (Btu)
1
54,400 68,000 92,000
Input - Low fire (Btu) - First Stage
1
47,600 59,500 80,500
Output - Low fire (Btu)
1
38,080 47,600 64,400
AFUE 80% 80% 80%
High 30-60 30-60 30-60
Low 25-45 30-50 25-45
Position All position All position All position
Gas Connection 1/2" NPT 1/2" NPT 1/2" NPT
NO
X
(Ng/J)
<40 <40 <40
ELECTRICAL DATA
Volts, Phase, Herz 115 / 60 / 1 115 / 60 / 1 115 / 60 / 1
Min. / Max. Voltage 102 / 132 102 / 132 102 / 132
Transformer (V.A.) 40 40 40
Min. Time Delay Breaker or Fuse
2
15 AMP 15 AMP 15 AMP
HEAT EXCHANGER
Number of Tubes 4 5 7
Approximate BTUs / Tube 17,000 17,000 17,000
Tube Diameter (inches) 1.5 1.5 1.5
Number of Passes 4 4 4
BLOWER PERFORMANCE DATA
A/C Cooling Max. (CFM) @.5 static 1,350 1,550 1,750
Blower Wheel 10 x 8 10 x 10 11 x 10
A/C Cooling Tons @ .5 esp 1.5 - 3.5 2 - 4 2.5 - 5
Motor Speed Variable Variable Variable
CABINET DIMENSIONS
Cabinet Width (inches) 17 1/2 20 1/2 22
Cabinet Height (inches) 35 35 35
Cabinet Depth (inches) 28 1/4 28 1/4 28 1/4
Volume (Cubic Feet) 10.28 12.05 12.93
P
ACKAGING DIMENSIONS
Package Width (inches) 21 1/4 24 1/4 25 3/4
Package Height (inches) 37 3/4 37 3/4 37 3/4
Package Depth (inches) 31 3/4 31 3/4 31 3/4
Loadability 40’ High Cube Container 116 104 100
Packaged Weight (lbs) 132 146 163
Temp. Rise