Fantom Vacuum FM743 Vacuum Cleaner User Manual


 
Caution:
Be sure that seal on the HEPAfilter is inserted
towards the inside of the vacuum cleaner.
The filter cover should be correctly oriented
when it is reattached. Do not reattach it upside down.
3
Insert a new HEPAfilter with the seal
to the inside of the vacuum cleaner.
Reattach the filter cover.
Caution:
Always replace the old filter with a new one.
2
Remove the HEPAfilter.
Under normal usage, the HEPA Filter will require replacement once every
three (3) months, however, vacuuming large amounts of extremely fine dust,
powder or similar material over a long period of time may decrease airflow
performance through the filter. If this occurs, it may become necessary to
replace the HEPA Filter more often. Only use genuine FANTOM
replacement filters.
15
REPLACEMENT INSTRUCTIONS
REPLACING THE FILTER
Caution: Do not wash the sub-filter in a washing machine, and do not use any other equipment
such as a hair dryer to dry it. Always allow 24 hours for drying. Do not operate
the vacuum without the sub-filter. Be sure the sub-filter is dry and properly installed.
Failure to do so could result in electrical shock, personal injury, or motor failure.
CLEANING THE SUB-FILTER
Clean the sub-filter when it becomes dirty.
Remove the dust compartment
(refer to page 8).
Remove the air inlet cover.
Remove the sub-filter from the vacuum cleaner.
Gently clean the sub-filter with water.
Make sure that it is completely dry and
then re-install it into the vacuum cleaner.
Replace the air inlet cover and the dust compartment.
1
2
3
4
1
and pull the filter cover away fromthe
vacuum cleaner.
1
Press in the locking tabs at points
Sub-Filter
Air Inlet
Cover
Do not attempt to wash the HEPA filter.
Note: We recommend replacing the sub-filter every three (3) to six (6) months, depending on usage.
Seal
HEPA Filter
Filter Cover
11
11
22