Fantom Vacuum FM732H Air Cleaner User Manual


 
Important: The suction hole must be
open, free of any obstructions at all
times. Otherwise, the motor will overheat
and could become damaged.
PLEASE NOTE
: The white pleated
filter material in the HEPA Dust Cup
Filter will discolor over time -This is
NORMAL and will NOT affect the
performance of the filter. If the HEPA
Dust Cup Filter
is properly
"TapCleaned”
after each use
and suction
does not return
to 100%, then
we suggest that
the HEPA filter
be “TapCleaned”
vigorously until
no more dust
can be removed, then rinsed under
the faucet and allowed to air dry for 24
hours before refitting into the vacuum.
(Fig. A) This should be done once a
month or when suction appears to
be reduced.
Fig. A
Warning: Allow 24
hours for drying before
replacing in unit.
Wash
once a
month or
when
suction
appears
reduced
Changing & Cleaning the
Pre-Motor Filter
The pre-motor filter is located
underneath the dust cup container.
This is a rinseable filter but should be
replaced every six (6) months. Never
operate the vacuum without ALL the
filters in place.
Push the Power On/Off button to the
"Off" position and disconnect the
power cord from the wall outlet.
Remove the dust cup container.
Remove the pre-motor filter and rinse
in lukewarm water, let dry completely.
Do not use a hair dryer to dry it. Air
dry only.
When filter is completely dry, replace
pre-motor filter back into the unit and
replace the dust cup container.
7.Vigorously “TapClean”
the HEPA Dust Cup
Filter on a hard
surface until no more
dust is observed
falling out from
between the pleats of
the filter. See
illustration at right.
Ensure that the filter assembly is
completely seated inside the dust
cup (container).
Important: Do NOT use the HEPA filter
cartridge without the debris screen in
place.
10. Re-install dust cup into the vacuum
and re-attach hose.
8. Reassemble the debris screen back
onto the HEPA filter cartridge.
9. To replace the HEPA
filter back into the
dust cup container,
hold the filter by the
stem and insert it up
into the dust cup
container making
sure that the top rim
of the filter fits onto
the top of the dust cup container and
twist it clockwise to lock in place.
OPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS
Assembling Your Vacuum Cleaner
4. Fitting the Floor to Carpet
Brush to the Telescopic Tube
Push the telescopic tube into the
floor brush as show in the
illustration below.
Note: Always remove the power plug
from the wall outlet before assembling or
removing accessories.
1. Attaching the Flexible Hose
into the Vacuum
Connect the flexible hose into the air
intake duct. Push in until you hear a
“click”, indicating it is in its locked
position.
To remove the flexible hose first
remove the power nozzle power cord
from the receptacle for the power
nozzle power cord, then depress
locking button and remove hose.
Connect the hose connecting power
cord from the flexible hose to the
power cord receptacle that is on the
unit just below the air intake duct.
Telescopic
Tube
Telescopic
Tube
Power
Nozzle
Floor to Carpet
Nozzle
1. Connecting the power nozzle with
the telescopic tube:
A) Depress the button on the
telescopic tube and insert it into
the slot on the power nozzle
elbow.
B) Push the telescopic tube down
until you hear a "click".
(see illustration below).
Using Power Nozzle
Air intake duct
Power cord receptacle
2. Fitting the Telescopic Tube
to the Curved Wand / Hose
Extension
Push the telescopic tube into the
curved wand / hose extension, as
shown in the illustration below.
Make sure that the telescopic tube
locks in place.
Plastic
Button
3. Extending the Telescopic Tube
Push forward on
the plastic button
and pull the inner
tube outward.
2. Insert the
motorized brush
power cord plug
into the power
socket on the
flexible hose. To
start motorized
brush press the
On/Off button that
is located on the
motorized brush.
7
4