EverFocus EPTZ2700i Home Security System User Manual


 
15
2.3. Initial Setup
Initial setup includes dome address, communication protocol, transmission speed, and
terminal resistance settings. All of the settings should be confirmed before the dome is
installed. The control-related setting that is address, communication protocol and
transmission speed have to be set consistently with the control device such as a keyboard
or a DVR.
Notice: Please make sure the power is off before setting, and restart the
EPTZ2700/EPTZ2700I to enable a new value after changing.
2.3.1. Address Setting
The address code of the EPTZ2700/EPTZ2700I should be set to correspond properly
with a control device to control multiple dome cameras. The address codes are made
up by the dipswitch on the camera main body. The 8 bits dipswitch indicates the binary
coded of the address, and there are 256 addresses can be selected (0 ~ 255). It also
means that there are up to 256 dome cameras that can cascade on the RS-485 bus.
The dipswitch setting and the indicated address are represented in the following
diagram.
Note: The factory default address is 1.
Notice: Please make sure the power is off before setting, and restart the
EPTZ2700/EPTZ2700I to enable a new value after changing.