Euro-Pro EP722 Vacuum Cleaner User Manual


 
OPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS
PLEASE NOTE: The white pleated
filter material in the HEPA Dust Cup
Filter will discolor over time -This is
NORMAL and will NOT affect the
performance of the filter. If the HEPA
Dust Cup Filter
is properly
"TapCleaned”
after each use
and suction
does not return
to 100%, then
we suggest that
the HEPA filter
be “TapCleaned”
vigorously until no
more dust can be removed, then
rinsed under the faucet and allowed to
dry for 24 hours before refitting into
the vacuum. (Fig. A) This should be
done once a month or when
suction appears to be reduced.
10.Attach the dust cup (container) to the
vacuum.
9. Reassemble the debris screen to the
HEPA filter cartridge and replace into
dust cup (container). Ensure that the
filter assembly is completely seated
inside the dust cup (container).
CAUTION: The suction hole must be
open, free of any obstructions at all
times. Otherwise, the motor will overheat
and could become damaged.
Fig. A
Wash once
a month or
when
suction
appears
reduced
Warning: Allow 24
hours for drying before
replacing in unit.
Changing the Pre-Motor Filter
Filter should be cleaned at least twice
a year or when it becomes visibly solid.
Always operate the cleaner with the
filter installed.
Disconnect from electrical outlet before
cleaning the filter.
1. Lift dust cup handle to remove
dust cup.
2. Remove the filter from the filter
grill.
3. Replace with a new filter and reinstall
in vacuum.
IMPORTANT
: Both the Pre-Motor and
the Micro Exhaust filters should be
replaced every 6 months or sooner if
required.
IMPORTANT
: All filters should be
checked regularly for signs of
damage, preferable after each
cleaning task. The filters must be
replaced immediately if they become
damaged.
Always disconnect the vacuum from
the electrical outlet when checking the
filters.
Changing the Micro-Exhaust
Filter
1. Remove the exhaust filter grill by
pulling the locking tabs towards
you.
2. Remove the used micro-exhaust
filter.
3. Insert a new micro-exhaust filter
and replace the filter grill.
Assembling Your Vacuum Cleaner
4. Fitting the Floor to Carpet
Brush or the Air Driven Turbo
Brush to the Telescopic Tube
Push the telescopic tube into the
desired floor brush as show in the
illustration below.
Note: Always remove the power plug
from the wall outlet before assembling or
removing accessories.
2. Fitting the Telescopic Tube
to the Curved Wand / Hose
Extension
Push the telescopic tube into the
curved wand / hose extension, as
shown in the illustration below.
Plastic
Knob
3. Extending the Chrome
Telescopic Tube
Push forward on the plastic button
and pull the inner chrome tube
outward.
Air Intake Duct
Floor to Carpet
Nozzle
5. Air Driven Turbo Brush
The efficiency of your Air Driven
Turbo Brush depends on the bristle
brush rotating at high speed. Strong
air suction is needed to accomplish
this. In order to endure that
maximum air suction is maintained,
please read the following instructions:
Empty the Dust Cup frequently during
use.
Always “TapClean” the HEPA dust
cup filter and debris screen each time
the dust cup is emptied.
Ensure that the rotating bristle brush
is kept free of hair and string.
Inspect the turbine regularly to ensure
that the air passage is free of dirt and
debris.
Hand Held Air Driven
Turbo Brush
Air Driven Turbo
Brush
1. Attaching the Flexible Hose
into the Vacuum
Connect the flexible hose into the air
intake duct. Push in until you hear a
“click”, indicating it is in its locked
position.
To remove the flexible hose
reverse
the operation.
Telescopic
Tube
Important: Do NOT use the HEPA filter
cartridge without the debris screen in
place.
4
7