Euro-Pro EP705 Vacuum Cleaner User Manual


 
Upright Vacuum
1
9. Exhaust Filter
10. Front Panel
11. Full Bag Indicator
12. On/Off Switch
13. Lock Plate
14. Motorized Power Head
15. Handle Release
16. Head Light
1. Upper Handle
2. Flexible Hose
3. Main Body
4. Dusting Brush
5. Hose Connector
6. Crevice Nozzle
7. Nested Extension Tubes (2)
8. Carpet Height Adjustment Knob
15
Turn unit “Off” and unplug from wall outlet.
Use a Phillips screwdriver and remove the two screws from the
back of the motorized power head cover.
Remove the two screws from the bottom of the motorized power
head.
With the base cover removed, remove the old light bulb and discard.
Insert new bulb into the socket and twist clockwise.
Replace the two screws from the bottom of the motorized power
head and then replace the cover. Then replace the two screws from
the back side of the motorized power head.
Note: Always replace the light bulb with the same or smaller wattage size
(12V 4W) to prevent damage to the surrounding parts.
5. Changing the Head Light Bulb:
Warning: Always disconnect from power source when servicing or
cleaning the unit. Failure to do so could result in electrical shock or
personal injury from cleaner suddenly starting.
Technical Specifications
Voltage: 120V~ 60Hz.
Power: 12 Amps
6