Clean Dust Cup Filter
CAUTION: Turn off the power switch and unplug
the electrical cord to service.
Clean dust cup filter as necessary.
1. Remove dust cup.
2. Remove dust cup lid and filter assembly.
3. Shake and brush the dust and dirt from filter. If desired,
launder the filter by hand in warm water using a mild
detergent. The filter may be washed up to 6 times. Air dry
thoroughly.
NOTE: The dust cup filter is not dishwasher safe.
Do not put in dishwasher.
4. Remove filter from dust cup lid by pressing the release tab
and lifing the filter out.
5. Replace filter in dust cup by twisting the dust cup lid firmly
into place to ensure proper filter performance.
6. Place bottom of dust cup in main housing. Push top of dust
cup back into place until it locks.
You may order replacement filters from Electrolux Home
Care Products N.A., Consumer Service, P. O. Box 3900,
Peoria, Illinois 61612. Order dust cup filter, Style DCF-10, PN
62396. To place an order please telephone 1-800-282-2886.
3
4
6
Brushroll Reset Switch
This vacuum comes equipped with a brushroll circuit protector
which turns the brushroll off in the event of a stall situation. The
reset switch is located on the right side of the power nozzle.
(see page 3)
CAUTION: Turn off the power switch and unplug the
electrical cord to service.
1. Turn off the vacuum and unplug it.
2. Remove the obstruction from the brushroll.
3. Plug the cleaner back in, press the reset switch and then
turn the vacuum on to continue cleaning.
4. Periodically remove hair and threads from the brushroll.
Hose and Attachments
CAUTION: Turn off the power switch and unplug
the electrical cord to service.
1. Pull the hose end from the hose retainer at the bottom of
the unit and the hose holder at the top.
2. Turn the hose actuator valve counter clockwise to direct air
from the floor nozzle to the hose end.
3. Attach hose wand, dusting brush or crevice tool.
4. After using attachments, remove hose wand, dusting brush
or crevice tool, store in designated holders.
5. Turn the hose actuator valve clockwise to direct air from the
hose end to the floor nozzle.
6. Wrap hose around the top hose holder and re-attach at the
bottom of the unit into the hose retainer.