Eureka 1400-1900 Series Vacuum Cleaner User Manual


 
Brush Roll Belt
The brush roll belt on the upright vacuum cleaner drives the brush to agitate, sweep,
and comb the carpet nap. The belt should be checked regularly to be sure it is in good
condition. Replace the belt if it is stretching, cracking, or slipping. Cut away any hair or
thread wound around the brush roll or the belt pulley because the buildup could cause
the belt to rotate unevenly.
How To Replace A Worn Belt
NOTE: Turn off the switch and unplug the electrical cord before replacing belt.
Belt pulleys can become hot during normal use. To prevent injury, avoid
touching the belt pulley when servicing the drive belt.
IMPORTANT: Improper installation of the brush roll or brush roll belt could cause
carpet or cleaner damage.
Look for the symbol.
13
Ask for GENUINE EUREKA
replacement belts No. 52100.
GENUINE
EUREKA PRODUCT
.
.
1
1
1. Release cam locks.
3
4
Belt
Guide
Check for brush wear, see Brush
Roll instructions.
3. Place new belt around
brush roll.
4. Align brush roll pulley with
belt guide.
Brush Roll Pulley
Motor
Pulley
2
2. Pull up on belt to rotate it off the
motor pulley. Lift up on brush roll
and remove worn belt.
6
5
5. Place rubber end cap covers over
both end caps (flat side against end
cap). Align holes and secure. Then,
slant brush roll forward so end
caps are in line with slots in cleaner
base.
6. Push brush roll into base
.
.
9
9
8
8
8. Place slots of bottom plate over
tabs of cleaner base.
9. Seat and secure cam locks
7
7. Place lower side of belt
into belt guide and pull to
stretch the belt around the
left side of the motor
pulley. Rotate pulley to
secure belt into groove.