Essick Air FAD242 Fan User Manual


 
4
110497
Problem Possible Cause Remedy
1. No electrical power to
unit
Fuse blown
Circuit breaker
tripped
2. Belt too loose or tight
3. Motor overheated
Belt too tight
Blower bearings dry
4. Motor locked
1. Insufficient air exhaust
2. Belt too loose
3. Pads plugged
4. Insufficient water
flow over pads
1. Low voltage
2. Excessive belt tension
3. Fan shaft tight or
locked
4. Bearings dry
5. Faulty motor
1. Check power
Replace fuse
Reset breaker
2. Adjust belt tension
3. Determine cause of
overheating
Adjust belt tension
Grease blower
bearings
4. Replace motor
1. Open windows or
doors to increase air
flow
2. Adjust belt tension
or replace if needed
3. Clean pads
4. Clean distribution
system
1. Check voltage
2. Adjust belt tension
3. Grease or replace
bearings (Disconnect
unit)
4. Grease bearings
5. Replace motor
Troubleshooting Guide
Problem Possible Cause Remedy
1. Stale or stagnate water
in cooler
2. Pads not wetting
properly
Dist. tube holes
clogged
Pump not working
properly
Insufficient water
flow over pads
1. Bearings dry
2. Loose parts
1. Inadequate exhaust in
building
2. Pads not wet
Pads plugged
Dist. tube holes
clogged
Pump not working
properly
1. Inadequate exhaust
1. Drain pan and clean
pads
2. Check water
distribution system
Clean
Replace or clean
pump (Unplug)
Clean water
distribution system
1. Grease bearings
2. Tighten loose parts
1. Open windows or
doors to increase air
flow
2. Check water
distribution system
Clean pads
Clean
Replace or clean
pump (Unplug)
1. Open doors or
windows
Failure to
start or no
air delivery
Inadequate
air delivery
with cooler
running
Motor
cycles on
and off
Musty or
unpleasant
odor
Noisy
Inadequate
cooling
Excessive
humidity
in building
Limited Warranty
This warranty is extended to the original purchaser of an evaporative cooler installed and used under normal conditions. It does not cover
damages incurred through accident, neglect, or abuse by the owner. We do not authorize any person or representative to assume for us any
other or different liability in connection with this product.
Terms And Conditions Of Warranty
Lifetime Limited Coverage on water reservoir against any leakage due to defects in material. From date of purchase, if any original
component part fails due to defect in material or factory workmanship only, we will provide the replacement part as follows:
One year on the cabinet components.
Two years on the evaporative media.
Exclusions From The Warranty
We are not responsible for any incidental or consequential damage resulting from any malfunction.
We are not responsible for any damage received from the use of water softeners, chemicals, descale material, plastic wrap, or if a motor of
a higher horsepower than what is shown on the serial plate is used in the unit.
We are not responsible for the cost of service calls to diagnose cause of trouble, or labor charge to repair and/or replace parts.
How To Obtain Service Under This Warranty
Contact the Dealer where you purchased the evaporative cooler. If for any reason you are not satisfied with the response from the dealer,
contact the Customer Service Department: 5800 Murray Street, Little Rock, Arkansas 72209. 1-800-643-8341. E-mail:
info@championcooler.com, Web: www.championcooler.com.
This limited warranty applies to original purchaser only