Essick Air AD2C5112 Fan User Manual


 
5
110498-3
Limited Warranty
This warranty is extended to the original purchaser of an evaporative cooler installed and used under normal conditions. It does not cover damages in-
curred through accident, neglect, or abuse by the owner. We do not authorize any person or representative to assume for us any other or different liability
in connection with this product.
Terms And Conditions Of Warranty
Lifetime Limited Coverage on water reservoir against any leakage due to defects in material. From date of purchase, if any original component part
provided by Champion Cooler fails due to defect in material or factory workmanship only, we will provide the replacement part as follows:
One year on the cabinet components.
Five years on the evaporative media.
Two years on the original blower motor if furnished by Champion Cooler.
Exclusions From The Warranty
We are not responsible for any incidental or consequential damage resulting from any malfunction.
We are not responsible for any damage received from the use of water softeners, chemicals, descale material, plastic wrap, or if a motor of a higher
horsepower than what is shown on the serial plate is used in the unit.
We are not responsible for the cost of service calls to diagnose cause of trouble, or labor charge to repair and/or replace parts.
How To Obtain Service Under This Warranty
Contact the Dealer where you purchased the evaporative cooler. If for any reason you are not satis ed with the response from the dealer, contact the Customer
Service Department: Champion Cooler, 5800 Murray Street, Little Rock, Arkansas 72209. 1-800-643-8341. E-mail: info@championcooler.com.
This limited warranty applies to original purchaser only.
Problem Possible Cause Remedy
Failure to
start or no air
delivery/ No
LCD display
Inadequate
air delivery
with cooler
running
1. No electrical power
to unit
Fuse blown
• Circuit breaker tripped
2. Motor overheated
• Belt too tight
• Blower bearings dry
• Motor pulley diameter
too large
3. Motor locked
4. Fuse blown in unit
control box
5. Incorrect wiring be-
tween wall thermostat
and cooler
6. Poor connection to
Fan motor terminals
7. Unit control board or
wall thermostat faulty
1. Insuf cient air exhaust
2. Belt too loose
3. Pads plugged
4. Motor underloaded
1. Check power
• Replace fuse
• Re-set breaker
2. Determine cause
• Adjust belt tension
• Oil blower bearings
• Adjust pulley to correct
diameter
3. Replace motor
4. Replace Fuse
5. Check that wiring is correct
and secured to terminals
6. Check connections to termi-
nal
7. Supply power to control box
and check DC voltage at
wall thermostat
• If voltage between Black
& Red terminals is close to
3.5VDC and LCD is blank
- wall thermostat is faulty
• If voltage is much less than
3.5VDC, remove red wire
from terminal. If voltage
rises to 3.5VDC - thermostat
is faulty. If voltage remains
low - unit control board is
faulty.
1. Open windows or doors to
increase air ow
2. Adjust belt tension or
replace if needed
3. Clean pads
4. Adjust pulley
Troubleshooting Guide
Problem Possible Cause Remedy
1. Float arm not adjusted
properly
2. Over ow assembly
leaking
1. Stale or stagnate water
in cooler
1. Low voltage
2. Excessive belt tension
3. Blower shaft tight or
locked
4. Bearings dry
5. Motor pulley diameter
too large causing motor
overload
1. Bearings dry
2. Wheel rubbing blower
housing
3. Loose parts
1. Inadequate exhaust in
house
2. Pads not wet
Pads plugged
• Dist. tube holes clogged
• Pump not working prop-
erly
3. Poor connection to Pump
terminals on Control
Board
1. Insuf cient air exhaust
1. Adjust oat
2. Tighten nut and over ow
pipe
1. Drain pan and clean pads
1. Check voltage
2. Adjust belt tension
3. Oil or replace bearings
(Unplug unit)
4. Oil bearings
5. Adjust pulley so full load
ampere rating of motor is
not exceeded
1. Oil bearings
2. Inspect and realign (Un-
plug unit)
3. Tighten loose parts
1. Open windows or doors to
increase air ow
2. Check water distribution
system
• Clean pads
• Clean
• Replace or clean pump
(Unplug unit)
3. Check connections
1. Open doors or windows
Water drain-
ing onto roof
Musty or
unpleasant
odor
Motor cycles
on and off
Noisy
Inadequate
cooling
Excessive
humidity in
house
Register your product online at www.championcooler.com/eac/onlineregistration-eac.htm