4
Display Panel: Humidity Display, Refill Indication
and Fan Indication
Fan Speed
Button
Humidity
Control
Button
Power
Button
9. This unit has one reservoir, which when emptied,
triggers the respective refill indication and
automatically shuts off the motor. The motor will start
again automatically when the reservoir is refilled.
10. When the reservoir is being filled for the first time, the
dry wick absorbs water, requiring more water on the
first fill up than subsequent fillings.
NOTE: We recommend using Essick Air Bacteriostat
Treatment when you refill the water reservoir to
eliminate bacterial growth. Add bacteriostat according
to the instructions on the bottle.
OPERATION
1. Plug cord into wall receptacle. Your humidifier is now
ready for use. The humidifier should be placed at least
FOUR inches away from any walls and away from heat
registers. Unrestricted airflow into the unit will result in
the best efficiency and performance.
2. The 800 Series 2-speed fan control allows you to use
the low setting for the quietest operation or a high
setting for maximum output.
3. This model has an automatic humidistat that cycles the humidifier on and off as
required to maintain the selected setting.
4. The digital controller has a display that provides
information on the status of the unit. Press the power
button and select fan speed – F1 for low speed and
F2 for high speed. At initial startup the relative
humidity of the room will be displayed. Each
successive push of the Humidity Control Button will
increase the setting
in 5% increments. At 65% set point,
the unit will operate continuously.
A flashing “F” indicates the reservoir is empty.
Check Filter Indicator
The ability of any humidifier to efficiently supply humidity output relies heavily on the
condition of the filter. As the filter loads with impurities it gradually loses its wicking
capability. When this happens, moisture output is reduced and the humidifier has to work
longer to satisfy the selected setting. This humidifier has a check filter reminder timed to
appear after 720 hours of operation. When the Check Filter (CF) message is displayed,
disconnect the power cord and check the condition of the filter. If a build-up of deposits or
severe discoloration is evident replace the filter to restore maximum efficiency. The CF