AIR CARE® FILTERS
The 5D6 700 has an optional two-stage air filter (#1050) that can be inserted into the top
of the chassis which filters the air as it humidifies.
The first stage of the air filter is a high-efficiency, electrostatically-charged filter media
which traps dust, pollen and airborne pollutants. The second stage of the Air Care filter is
an activated carbon media which absorbs odors from cooking, pets or tobacco smoke.
We recommend replacing the Air Care filter at least once a year, more often if
necessary. When the white filter media is coated with a layer of dust and dirt, it is time to
replace the filter.
The certified water output of your humidifier will be reduced when using the Air Care
filter. The Air Care filters are optional and are not required for normal operation of the
humidifier.
CARE AND MAINTENANCE
CAUTION: Disconnect power before filling, cleaning or servicing unit. Keep chassis
dry at all times.
CLEANING / DISINFECTING INSTRUCTIONS
1) Turn unit off then unplug electrical cord from the wall outlet.
2) Lift off chassis, and transitional molding from cabinet and set aside.
3) Lift wicks from cabinet, allow water to drain from wicks into cabinet and then set aside.
4) Empty cabinet into sink. Remove any remaining water from cabinet with a sponge.
5) Fill reservoir with water and then add 8oz. (1cup) of undiluted white vinegar. Let solution
stay 20 minutes, then empty.
6) Clean all interior surfaces of reservoir with a soft brush. Dampen soft cloth with undiluted
white vinegar and wipe out reservoir to remove scale.
7) Rinse cabinet thoroughly with fresh water and remove scale and cleaning solution.
DISINFECTING RESERVOIR
8) Fill reservoir with water and add 3 teaspoons of chlorine bleach. Let solution stand for 20
minutes.
9) Empty and rinse thoroughly. Refill unit with water and reassemble unit.
SUMMER STORAGE
1) Clean unit as outlined in Care & Maintenance section.
2) Discard used wicks and any water in the reservoir and allow cabinet to dry thoroughly
before storage. Do not store with water inside reservoir.
3) Do not store unit in an attic or other high-temperature area.
4) Install new filter at beginning of season.